U101
Primary transfer voltage adjustment
(Message: Adjust 1st Transfer Voltage Output)
Contents
Set the primary transfer control voltage
Purpose
Change setting if a failure such as faint image, etc. occurs.
Setting
1.Press the [Start] key.
2.Select the item to set.
3.By using the [+] [-] keys or the numeric keys, change the setting value.
On Timing
Off Timing
Pre On Timing
Pre Bias
Rev Bias
Bias(L)
Bias(M)
Bias (S)
4.Press the [Start] key to set the setting value.
Precautions
Test copy of the original is available by pressing the [System Menu] key as interruption copy mode when
executing this maintenance mode.
Completion
Press the [Stop] key.
*: The screen for selecting a maintenance item No. is displayed.
Items
On Timing setting
Off Timing setting
Pre On Timing setting
Pre Bias setting
Rev Bias setting
Bias(L) setting
Bias(M) setting
Bias (S) setting
Contents
1-3-64
Setting range
Initial
setting
-1000 to 1000
0
-1000 to 1000
-70
-1000 to 1000
0
0 to 2400
70
0 to 2400
190
100 to 2400
775
100 to 2400
915
100 to 2400
1288
2RG/2RH