Check the copy image after the adjustment. If the image is still incorrect, adjust the following in the mainte-
nance mode.
U034 > U066(P.1-3-47) > U071(P.1-3-51)
Adjustment: LSU Out Left
1.Select the item to adjust.
2.Press the [System Menu] key.
3.Press the [Start] key to output a test pattern.
4.Press the [System Menu] key.
Items
MPT
Cassette1
Cassette2
Cassette3
Cassette4
Duplex
5.By using the [+] [-] keys or the numeric keys, change the setting value.
For the test pattern 1, increase the value.
For the test pattern 2, decrease the value.
*: When the setting value is increased, the image moves to right, and it moves to left when the setting
value is decreased.
Center line of printing
(within ± 2.0 mm)
6.Press the [Start] key to set the setting value.
Precautions
Check the copy image after the adjustment. If the image is still incorrect, adjust the following in the mainte-
nance mode.
U034 < U067(P.1-3-48) < U072(P.1-3-53)
Completion
Press the [Stop] key.
*: The screen for selecting a maintenance item No. is displayed.
Contents
Adjust the center line for the MP tray
Adjust the center line for cassette 1 feed
Adjust the center line for cassette 2 feed
Adjust the center line for cassette 3
(Optional unit) feed
Adjust the center line for cassette 4
(Optional unit) feed
Adjusting the center line when duplex
copying (Back page)
Correct image
example 1
Figure 3-6
Output
Output
example 2
1-3-37
Setting range
Initial
setting
-128 to 127
0
-128 to 127
0
-128 to 127
0
-128 to 127
0
-128 to 127
0
-128 to 127
0
2RG/2RH
Data
varia-
tion
0.1mm
0.1mm
0.1mm
0.1mm
0.1mm
0.1mm