Kyocera Copystar CS 3011i Service Manual page 236

Table of Contents

Advertisement

U601
Initialize: Keep data
(Message: Initialize: Keep Data)
Contents
Initializes software switches other than the machine data on the FAX PWB according to the destination and
OEM setting.
Purpose
Initialize the FAX PWB without changing the user registration data and the factory defaults
Method
1.Press the [Start] key.
2.Select [Execute].
*: The screen for entering the destination code and OEM code is displayed.
Execute
3.Select [Country Code].
4.By using the [+] [-] keys or the numeric keys, change the setting value.
*: Refer to the destination code list. (P.1-3-151See page )
Country Code
OEM Code
*: No need to change the default value of [OEM Code].
5.Press the [Start] key to set the setting value.
*: Data initialization starts.
Press the [Stop] key to cancel the data initialization.
6.The firmware version is displayed after the data initialization.
The firmware version of 3 types of application, boot and IPL is displayed.
*: When initialization is successful, "Completed" is displayed for one second.
Items
Executing data initialization
Items
Setting Destination code
Sets the OEM code
Contents
Contents
1-3-153