WIRING PROCEDURE

• Properly route the wire harness according to the "WIRING
HARNESS ROUTING" section. (10-12 to -14)

USING THE MULTI CIRCUIT TESTER

• Properly use the multi circuit tester + and - probes.
Improper use can cause damage to the motorcycle and
tester.
• If the voltage and current values are not known, begin mea-
suring in the highest range.
• When measuring the resistance, make sure that no voltage is
applied. If voltage is applied, the tester will be damaged.
• After using the tester, be sure to turn the switch OFF.
 09900-25008: Multi circuit tester set
Before using the multi circuit tester, read its instruc-
tion manual.
NOTE:
* When connecting the multi circuit tester, use the needle-point
probe to the back side of the lead wire coupler and connect
the probes of tester to them.
* Use the needle-point probe to prevent the rubber of the water
proof coupler from damage.
 09900-25009: Needle-point probe set
• When using the multi circuit tester, do not strongly touch the
terminal of the ECM coupler with a needle-point probe to pre-
vent the terminal damage or terminal bend.
ELECTRICAL SYSTEM 9-5