Position Table; Teaching Of Positions - WAGO I/O SYSTEM 750 750-671 Manual

Fieldbus independent i/o modules
Table of Contents

Advertisement

Example: Eight (8) entries are to be loaded to the camshaft table.
Step No.
1
2
3
4
5
6
7
8
The portion of the table highlighted in gray must be downloaded to the
module.
The checksum for the table must also be calculated. To do this, the sum is
taken over all the bytes. Here, the checksum is 0xb0d.
Opcodes given in Chapter 3.1.4.4, „Table Management Commands" are
required for downloading.
The corresponding opcodes have been adapted in the following table for this
case. For the complete scope and explanations, refer to the sections cited
above.
2.1.2.12.3

Position Table

The position table enables a set Move program sequence containing variable
positions to be run.
Up to 50 positions can be stored in the position table that can be queried by
Move commands. The position table entries can be evaluated on the basis of
absolute or relative Move commands.
The position table can be downloaded. As an alternative to this, individual
entries can be written or "taught" as absolute or relative positions with the
current position.
2.1.2.12.3.1

Teaching of Positions

Teaching of positions using the mailbox command POS_TABLE_TEACH
allows the current actual value to the saved in the position table so that it is
available as a target for a Move task.
WAGO-I/O-SYSTEM 750
I/O Modules
CAM
8 7 6 5 4 3 2 1 Byte 4
1 0 0 0 0 1 0 0 0x00
0 1 0 0 0 1 0 0 0x00
0 0 1 0 0 0 1 0 0x00
0 0 0 1 0 0 1 0 0x01
0 0 0 0 1 0 0 0 0x01
0 1 0 0 0 1 0 0 0x02
0 1 0 0 0 0 1 0 0x07
0 1 0 0 0 0 0 1 0x07
750-671 [Steppercontroller]
Expanded Positioning Functions
Position
Byte 3
MB5
MB4
0x2e
0x5d
0xbb
0x77
0xd4
0x90
0xb0
0xdf
• 109
Outputs
Byte 2
Byte 1
MB3
MB 3
0xe0
0x84
0xc0
0x44
0x80
0x22
0x00
0x12
0xc0
0x08
0x40
0x44
0xc0
0x42
0xa0
0x41