46 •
750-671 [Steppercontroller]

Technical Data

2.1.2.6
Technical Data
Inputs
Number of inputs
Input characteristik
Input voltage
Signal voltage (0)
Signal voltage (1)
Input filter
Input current
Outputs
Number of outputs
Operating modes
Resolution
Microstepping
Output current
Protective functions
Module Specific Data
Voltage supply
Current consumption
(system voltage 5 V DC)
Current consumption
(power jumper contacts 24 V DC)
Voltage via power jumper contacts
Current via power jumper contacts
Electrical isolation
.
typ
Path
Velocity
Acceleration
max.
ca.
ca.
max.
2 (DI1+, DI2+)
Type 1 accordance with IEC61131-2 ( 2004)
DC -3 V ... 30 V
DC -3 V ... +5 V
DC 15 V ... 30 V
100 μs
2.8 mA
2 Outputs A1, A2 and B1, B2 for the connection
of motor windings
Positioning, Referencing, Jog Mode, Move
program
23 Bit + sign
15 bit + sign
15 bit + sign
64 times internally
1)
1 A Nominal current
per phase
1.5 A Short-time current
The derating factor is 1 % Kelvin from an
ambient operating temperature of 25 °C (see Fig.
1.1.1 8: Derating graph)
- Short circuit of motor windings is permitted
- Short circuit of motor windings against 0 V or
24 V results in the destruction of the output
stage
- Reverse polarity of the 24 V supply
- Excess temperature of the output stage results
in
2)
shutdown
via system voltage internal bus (5 V DC) and
power jumper contacts (24 V DC)
85 mA
0 mA + load
24 V DC (-15 % ... +20 %)
Protected against reverse polarity
10 A
500 V DC system voltage / field level (power
jumper contacts)
WAGO-I/O-SYSTEM 750
1)
per phase