Cyclic Process Image - WAGO I/O SYSTEM 750 750-671 Manual

Fieldbus independent i/o modules
Table of Contents

Advertisement

50 •
750-671 [Steppercontroller]
Process Image
2.1.2.7.3

Cyclic Process Image

The process image appears as follows when the mailbox is deactivated (C0.5
= 0):
Off-
set
10
11
The configuration of the process data depends on the set operating mode; this
is described in the associated sections.
A basic distinction is drawn between the following process images:
- Positioning,
- Jogging,
- Move program,
- Velocity.
Input Data
0
S0
Status byte S0
1
Reserved
2
D0
Process data
3
D1
Process data
4
D2
Process data
5
D3
Process data
6
D4
Process data
7
D5
Process data
8
D6
Process data
9
S3
Status byte S3
S2
Status byte S2
S1
Status byte S1
Output Data
C0
Control byte C0
Reserved
D0
Process data
D1
Process data
D2
Process data
D3
Process data
D4
Process data
D5
Process data
D6
Process data
C3
Control byte C3
C2
Control byte C2
C1
Control byte C1
WAGO-I/O-SYSTEM 750
I/O Modules

Advertisement

Table of Contents
loading

Table of Contents