Wiring Hysecurity Sensors: Smart Touch - HySecurity UL 325 Quick Start - Supplemental Instructions

Table of Contents

Advertisement

Wiring HySecurity Sensors: Smart Touch

Wiring diagrams are provided on the following pages. The diagrams illustrate how to connect sensors and program the
gate operator. HySecurity Smart Touch gate operators can monitor entrapment protection sensors per UL 325 - 2015
Standard of Safety using software version h4.50 (or higher).
The site designer or installer must determine which external entrapment protection sensors will be installed with the
gate operator to create a UL 325 compliant installation site. For additional information, review For additional information,
review
Gate Safety on the HySecurity website.
Power Supply Board
Label: pre-2016
EDGE SENSOR
EDGE SENSOR
PHOTO EYE POWER
PHOTO EYE POWER
24 VOLTS COMMON
24 VOLTS COMMO
PHOTO EYE POWER
PHOTO EYE POWER
DO NOT USE
PHOTO EYE
PHOTO EYE
OPEN DIRECTION
OPEN DIRECTION
DO NOT USE
PHOTO EYE
PHOTO EYE
CLOSE DIRECTION
CLOSE DIRECTION
Label:
Pre-2016
Build Year (BY 1)
MX3979-02
Used on replacement boards for gate
operators manufactured prior to 2016.
www.hysecurity.com © 2016
Label: 2016
SENSOR 1
SENSOR 1
SENSOR
SENSOR
COM
COM
DO NOT USE
SENSOR 2
SENSOR 2
DO NOT USE
SENSOR 3
SENSOR 3
Label:
Post 2016 Label
Build Year (BY 2)
MX3978-01
Change effective January 12th 2016
per UL 325 - 2016 Standard of Safety
DRIVE
1
STOP BUTTON
2
OPEN BUTTON
3
CLOSE BUTTON
REMOTE OPEN AND
4
RADIO CONTROL
5
OPEN/CLOSE
6
OPEN PARTIAL
INTERLOCK OPEN
7
TIME CLOCK OPEN
8
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
9
DISABLE CLOSE TIMER
10
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
11
VEHICLE DETECTOR
SHADOW/RESET
12
VEHICLE DETECTOR
EDGE SENSOR
14
PHOTO EYE POWER
24 VOLTS COMMON
15
PHOTO EYE POWER
16
DO NOT USE
PHOTO EYE
17
OPEN DIRECTION
18
DO NOT USE
19
PHOTO EYE
CLOSE DIRECTION
20
DO NOT USE
CHARGER
21
AC LOSS
22
LOCK INTERLOCK
23
EMERG CLOSE
24
FIRE DEPT OPEN
Smart Touch Controller
LED
LIMIT
DUAL GATE
RPM
COM
A
S2 6 (EDGE BOTH)
SENSOR #2 TYPE
Quick Start
POWER
RS485
COM
NO
STATUS
HySecurity
MX000585
VERSION
S/N
RADIO OPTIONS
S 1
B
COM
OPEN
+24V
+24V
COM
D0726 Rev. J
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents