Figure 13: Processor air duct
5. Lift the air duct from the server platform and store it in a safe location.
To replace the processor air duct
1. Place the processor air duct over the processor socket and four-fan assembly. Make
2. Tighten the screws at the top of the air duct. The top of the installed air duct must
3. Replace the chassis cover. Refer to
4. Take the ESD strap off.

Replacing the power supply

The power supplies are hot-swappable and you can replace each power supply without
powering down the server.
Important:
Do not remove both power supplies while the system is running. Shut down the multimedia
channels by using the Courtesy Stop in Avaya CallPilot Manager. Shut down the server
using the Windows Shut Down option, and unplug the power supplies before removing both
power supplies at the same time.
Avaya CallPilot® 1005r Server Maintenance and Diagnostics
sure you do not pinch any wires beneath the edges of the air duct. Refer to
Processor air duct
on page 73.
be flush with the top surface of the PCI adapter assembly.
page 70.
Replacing the power supply
Removing and replacing the server cover
Figure 13:
on
December 2010
73