Requirements - Avaya CallPilot 1005r Maintenance And Diagnostics

Hide thumbs Also See for CallPilot 1005r:
Table of Contents

Advertisement

Replacing or adding voice processing boards

Requirements

• Phillips (cross head) screwdriver, #1 and #2 bit
• MPB96 replacement board
• electrostatic discharge (ESD) grounding strap
To replace an MPB96 board
1. Courtesy stop all Avaya CallPilot channels. Refer to
2. Power down the server, unplug all peripheral devices and ethernet cables, and
3. Attach the ESD strap to your wrist and attach the other end to a known grounded
4. Remove the chassis cover. Refer to
5. Disconnect the red power cable from the PCI riser assembly.
6. Disconnect the DS30X cable or DS30 cables from the MPB96 board in the full-
108
Avaya CallPilot® 1005r Server Maintenance and Diagnostics
components
on page 51.
disconnect the AC power.
connection.
page 70 for instructions.
size side of the PCI riser.
Starting and stopping
Removing and replacing the server cover
on
December 2010

Advertisement

Table of Contents
loading