Appendix C: Output Types - Pyronix 256 System Manual

Table of Contents

Advertisement

P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
Type
0000
Not Used
0001
Fire
0002
Hold Up Any
0003
Intruder Any
0004
Final Arm All*
0005
Misoperation Any (Abort)
0006
Confirmed Any
0007
Tamper Any
0008
Duress
0009
HU Device Any
0010
Gas
0011
Arm Fail
0012
Entry Deviation
0013
Secure Intruder Any
0014
Bell Any
0016
Strobe Any
0017
Omit Rearm Any
0018
Unconfirmed Any
0019
Can All Arm*
0020
Exit Starts All*
NOTE: For 'exit starts' to be entered in system logs, the site option 'Confirmed when...' must be
set to 'exit start'
0021
Exit Starts Any
0022
Final Arm Any
0023
Strobe Set Fail
0025
Keyswitch unset
Set with Omit (Not on
0026
PCX 256)
0031
Entry*
0032
Exit*
0033
Entry/Exit
0034
Lights
Page: 150
A P P E N D I X E :
Active
At alarm
At a HU or Duress alarm
(This includes keypad HU)
At alarm, while system is
disarmed
When system is FULLY armed
When system is silenced after
any 'intruder' output is
triggered
When further input active in
any partition after 'intruder'
alarm
Any tamper alarm
At a Duress alarm (i.e. from a
keypad)
At alarm on a HU input only
At alarm
Pre-set time after start of exit
time, if exit procedure is not
complete
When deviation from entry
route occurs, during entry time
At alarm, after exit time started,
until disarm
When alarm live
When alarm live
At rearm at end of confirm time
if an input in fault is isolated
Any intruder or Tamper alarm
If all inputs and technical faults
in system are clear. Also once
entry time has started
At start of exit time to arm
LAST partition
When exit time starts to arm
FIRST partition
When FIRST partition is armed
Works similar to output 016, but also fires if the set fail timer
expires.
This output turns on for 5 seconds when the system is disarmed
via a keyswitch input (either pulsed or latched keyswitch)
Activates when inputs are omitted on an arming mode
Live during any exit time
Live during any entry time
Live during any entry or exit time
When exit or entry timer starts
O U T P U T T Y P E S
Restore
When a valid code is entered
When a valid code is entered
At first valid code entry
At code entry to disarm
After 2 minutes
At next code entry
At code entry to silence
When a valid code is entered
When a valid code is entered
When a valid code is entered
At code entry to rearm
At code entry to disarm
At first valid code entry
When alarm silenced or when
siren timer expires
When alarm silenced or when
strobe timer expires
When system disarmed
At code entry to silence
If fault exists, and after final
arm
At code entry to disarm FIRST
partition (i.e. no longer fully
armed)
At code entry to disarm LAST
partition
At code entry to disarm LAST
partition
20 seconds after arm/disarm
RINS871-3