1 2 . 6 F o r c e d A r m O n I n p u t s
The 'Forced Arm On Inputs' allows the Engineer to arm / disarm the system using the Engineer Code,
forcing it to arm despite inputs in fault condition, and nominate which inputs must be triggered to generate an
alarm condition.
This is a useful feature if you need to test a system in a building where people are walking around.
NOTE 1: The system will give the correct DigiCom response to the arming, and any resulting alarm.
On disarming the system (With the Engineer code or the User code), the system will revert to normal mode.
NOTE 2: If the system has been armed by any other code, the Engineer code will not disarm it.
V i s u a l K e y p a d P r o g r a m m i n g P r o c e d u r e
Enter the Engineer Code (default 9999).
Any active faults will be displayed, press the
key.
Press the
key again.
'FORCED ARM ON INPUT' will be displayed
Select the first input to be forced armed and press
the
key.
Select the second input to be forced armed and
press the
key.
Select the partition(s) / level arm you would like to
arm. Press the
key. The system then will begin
to arm.
When the input is triggered (or open and closed
again) the alarm will be activated.
Please note the primary partitions are A,B,C and D.