Input Attributes - Pyronix 256 System Manual

Table of Contents

Advertisement

Number & Type
16
Fault
Closure
17
Supervision
18
Shunt Input
19
Disarm Input
Keyswitch
20
Latched
Entry Shock
21
Input
Keyswitch
23
Pulsed
Attribute
Response Modification
System loudspeaker(s) will 'chime' when a input triggered whilst the alarm panel is disarmed.
Chime
Note: The input concerned will not indicate on the display.
Single
System chimes once when the input is triggered.
Follow
System chimes until the input is cleared.
Applicable to Immediate, Entry/Exit and Access input types
Omittable
Enables the input to be manually omitted during the arming procedure.
Double
The control will only generate an alarm if this input is triggered twice within a (programmable)
Knock
pre-set period, or if the input remains in fault condition for that period.
The control will only generate an alarm if this input, and another like-programmed input with
Dual Trip
adjacent number, are in fault condition at the same time. Either input in fault condition will
prevent the system from arming.
Enables the system to respond correctly when detectors of 'normally open' configuration are
Normally
wired to the system. Alternatively converts input types which default to 'normally open' (e.g.
Open
PTS) to operate with normally closed devices.
*Monitor
Enables an input to generate an alarm if the input does not see any activity for a period
Activity
specified by the NAT (Non Activity Time) timer.
Forces a log entry when the input is opened or closed, even when an alarm does not result.
*Special
Logged
May be selected to apply when a system is armed, when disarmed, or always.
*Paired
DO NOT USE THIS OPTION
Input
Input will not confirm an alarm triggered by another input from the same group. Groups 01 to
99 available. Default 00 denotes NOT PART of a group. Inputs allocated to Group 99 will
Confirm
generate an alarm that results in an intruder (unconfirmed) signal to an ARC. They will NOT
Group
under ANY circumstances generate a confirmed signal, regardless of which group the input
that triggered the 'unconfirmed' alarm is allocated to.
Not available on the PCX 26/SMS
RINS871-3
Operation
Active when armed or disarmed
Audible Response: Graduated internal
Triggers 'Global Fault 1 and 2' outputs if the system is armed.
Triggers 'Global Fault 2' output if the system is disarmed.
Active during arming procedure
No audible or communicator response
Prevents system being armed whilst active
Active at all times (Not available on PCX 26/SMS)
No audible or communicator response
Accepts input from keyswitch (or equivalent) to shunt the inputs assigned to it.
Associated outputs are available
Active when armed (Not available on PCX 26/SMS)
Accepts input from keyswitch (or equivalent) to disarm the arm level assigned to it.
Accepts input from keyswitch (or equivalent) to arm/disarm the arm modes assigned
to it. Arming includes normal exit time, etc. This is latched.
Active when system armed
Works in conjunction with EE input type for detection of forced entry. See page 50
for details.
Accepts input from keyswitch (or equivalent) to arm/disarm the arm modes assigned
to it. This pulses the arm/disarm state.
I n p u t A t t r i b u t e s
P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
Page: 149