Tag Reader Wiring (Pcx-Prox/Int); Connecting The Pcx-Prox/Int; Addressing The Pcx-Prox/Int - Pyronix 256 System Manual

Table of Contents

Advertisement

P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
1 7 . 7 T a g R e a d e r W i r i n g ( P C X - P R O X / I N T )
A maximum of 3 internal tag readers can be installed onto the PCX 26/SMS system and a maximum of 15
can be installed onto the PCX 256 system.

17.7.1 Connecting the PCX-PROX/INT

COMMS PGMS
NC1
C1
NO1
NC2
C2
NO2
AUX+
SPK
TR
B+

17.7.2 Addressing the PCX-PROX/INT

NOTE: Tag Readers are addressed using the address selection switches on the PCB. Open
the links to add up to the address as shown in the following table.
Address
1
00*
C
01
O
02
C
03
O
04
C
05
O
06
C
07
O
Make sure that the reader is addressed correctly – please see page: 60.
The reader also has 2 inputs on board and an output that can be used. Please see page Error! Bookmark
not defined. to see how the inputs are addressed for each panel.
Please note a PCX-RIX2 will connect the same way and needs to be programmed as 'Reader'
Page: 122
COMM UNICATION CARD
EXPANSION CARD SLOT
TAMPER
PGMS
RESET
F1
BELL
B-
F3
F2
470Ω Resistor
connected to
the control panel
and to the device
which is furthest
away
Power
Alarm
Tamper
Fault
Unset
Tag
D1 D2 D3 D4 K1 K2 K3 K4 L1 L2 L3
Switch
2
4
C
C
C
C
O
C
O
C
C
O
C
O
O
O
O
O
C = Switch Closed
A-1 B-1
RS232
F4
F5
ENGINEER
KEYPAD
Spare
Input 1
PIR
Detector
Address
8
C
08
C
09
C
10
C
11
C
12
C
13
C
14
C
15
O = Switch Open
A
B
BATTERY
CONNECT
4
4
+AUX-
K
K
7
7
ALARM
ALARM TAMPER
SUPPLY
Input 2
PIR
Detector
Switch
1
2
C
C
O
C
C
O
O
O
C
C
O
C
C
O
O
O
4
8
C
O
C
O
C
O
C
O
O
O
O
O
O
O
O
O
RINS871-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcx 26/sms

Table of Contents