Appendix D. Output Types; Unconfirmed Any; Final Set Any - Pyronix Enforcer 32-WE Programming And Installation Manual

Wireless alarm system
Hide thumbs Also See for Enforcer 32-WE:
Table of Contents

Advertisement

A p p e n d i x D . O u t p u t T y p e s
Type
0000
Not Used
0001
Fire
0002
Hold Up Any
0003
Intruder Any
0005
Misoperation Any (Abort)
0006
Confirmed Any
0007
Tamper Any
0008
Duress
0009
HU Device Any
0010
Gas
0011
Set Fail
0012
Entry Deviation
0013
Secure Intruder Any
0014
Siren Any
0016
Strobe Any
0017
Omit Rearm Any
0018

Unconfirmed Any

0021
Exit Starts Any
0022

Final Set Any

0023
Strobe Set Fail
0025
Keyswitch unset
0026
Set with Omit
0028
Power Fault
0029
Confirmed Intruder Any
0030
Confirmed Hold Up Any
0033
Entry/Exit
Active
At alarm
At a HU or Duress alarm
(This includes keypad HU)
At alarm, while system is
disarmed
When system is silenced after
any 'intruder' output is
triggered
After two 'intruder' alarm
activations
Any tamper alarm
At a Duress alarm (i.e. from a
keypad)
At alarm on a HU input only
At alarm
Pre-set time after start of exit
time, if exit procedure is not
complete
When deviation from entry
route occurs, during entry time
At alarm, after exit time
started, until unset
When alarm live
When alarm live
Input omitted if active (or in
alarm condition) at the end of
confirmation time.
Any intruder or Tamper alarm
When exit time starts to set
FIRST area
When FIRST area is set
Works similar to output 016, but also fires if the set fail timer
expires.
This output turns on for 5 seconds when the system is disarmed
via a keyswitch input (pulsed or latched)
Activates when inputs are omitted on setting
Active during low volts and battery faults
entry after fault cleared.
When more than one intruder
alarm activates
When more than one
confirmed hold up activates
Live during any entry or exit time
Page: 51
Restore
(permanently off)
When a valid code is entered
When a valid code is entered
At first valid code entry and at
end of confirm time.
After 2 minutes
At next code entry
At code entry to silence
And at end of confirm time.
When a valid code is entered
When a valid code is entered
When a valid code is entered
At code entry to rearm
At code entry to unset
At first valid code entry
and at end of confirm time.
When alarm silenced or when
siren timer expires
When alarm silenced or when
strobe timer expires
When system disarmed
At code entry to silence
At code entry to unset LAST
area
At code entry to unset LAST
area
. Restores at code
*
At next code entry
At next code entry