Timer
Function
a supervision fault. This must be programmed to 2 hours or less for
compliance to EN50131.
Wireless
This option is only applicable if wireless devices are installed. It is the
Jamming Time
time window that if a wireless device had its signal 'blocked' a fault
would display. For example, if the time is set to 30 seconds, then if a
wireless device is 'jammed' longer than 30 seconds a fault will be
displayed. This must be programmed to 30 seconds or less (but not
zero) for compliance to EN50131.
Service Time
This is a timer that can be set in days, and will display a message to
the user warning that a service is due. An engineer code will clear the
message.
A p p e n d i x D . O u t p u t T y p e s
Type
0000
Not Used
0001
Fire
0002
Hold Up Any
0003
Intruder Any
0004
Final Set All
0005
Misoperation
0006
Confirmed Any
0007
Tamper Any
0008
Duress Any
0009
HU Device Any
0010
Gas
0011
Set Fail
0012
Entry Deviation
0013
Secure Intruder Any
0014
Siren Any
0016
Strobe Any
0017
Omit Rearm Any
0018
Unconfirmed Any
0019
Can Set All
0020
Exit Starts All
Enforcer: Programming Manual
Active
At alarm
At a HU or Duress alarm
(This includes keypad HU)
At alarm, while system is
disarmed
When system is FULLY armed
When system is silenced after
any 'intruder' output is
triggered
After two 'intruder' alarm
activations
Any tamper alarm
At a Duress alarm (i.e. from a
keypad)
At alarm on a HU input only
At alarm
Pre-set time after start of exit
time, if exit procedure is not
complete
When deviation from entry
route occurs, during entry time
At alarm, after exit time
started, until unset
When alarm live
When alarm live
Input omitted if active (or in
alarm condition) at the end of
confirmation time.
Any intruder or Tamper alarm
If all inputs and technical faults
in system are clear. Also once
entry time has started
At start of exit time to arm
Page: 37
Restore
(permanently off)
When a valid code is entered
When a valid code is entered
At first valid code entry and at
end of confirm time.
At code entry to disarm
After 2 minutes
At next code entry
At code entry to silence
And at end of confirm time.
When a valid code is entered
When a valid code is entered
When a valid code is entered
At code entry to rearm
At code entry to unset
At first valid code entry
and at end of confirm time.
When alarm silenced or when
siren timer expires
When alarm silenced or when
strobe timer expires
When system disarmed
At code entry to silence
If fault exists, and after final
arm
At code entry to disarm FIRST
Range
0-100 seconds
367 days
Need help?
Do you have a question about the ENFORCER Series and is the answer not in the manual?
Questions and answers