Input; Connecting The Pcx-Rix8+/Psu - Pyronix 256 System Manual

Table of Contents

Advertisement

1 7 . 1 0 R e m o t e I n p u t E x p a n d e r ( P C X - R I X 8 + / P S U )
Every PCX-RIX8+ will come with its own power supply. Please note when connecting the RIX PSU, the
terminal "D2" should not be connected to the control panel.

17.10.1 Connecting the PCX-RIX8+/PSU

COMMUNICATION CARD
COMMS PGMS
EXPANSION CARD SLOT
TAMPER
NC1
C1
NO1
PGMS
NC2
C2
F1
NO2
AUX+
SPK
BELL
TR
B-
B+
F2
470Ω Resistor
connected to
the control panel
and to the device
which is furthest
away
THE D2 TERMINAL MUST
NOT BE CONNECTED TO
THE CONTROL PANEL
D1
RS-485 0V Supply
D2
RS-485 +12V Supply
RS-485 'A' Data
D3
RS-485 'B' Data
D4

Input 1

Z1
Input Common
COM
Input 2
Z2
Auxiliary -0V Supply
-
Auxiliary +12V Supply
+
Input 3
Z3
Input Common
COM
PGMs
Programmable Outputs
RINS871-3
P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
A-1
RS232
RESET
F3
F4
F5
ENGINEER
KEYPAD
D1-
D2+
D3
D4
E1-
E2+
E3
E4
-
Z1
COM
Z2
Z4
-
B-1
A
B
Power Supply Specification
Power Supply: 1.5A
Mains:
Mains Fuse:
Output:
Battery Fuse:
Output Fuse:
BATTERY
CONNECT
RIX Connects via 2 connectors.
ON
32
16
8
4
2
TAMPER
1
FAULT
ADDRESS
-
-
+
+
+
Z3
COM
Z4
Z5
COM
Z6
Z7
COM
Z8
Power Supply
Input 4
Auxiliary -0V Supply
Auxiliary +12V Supply
+
Input 5
Z5
Input Common
COM
Input 6
Z6
Auxiliary -0V Supply
-
Auxiliary +12V Supply
+
Input 7
Z7
Input Common
COM
Input 8
Z8
TAMPER
Tamper Inputs
220-240V AC 50Hz 150mA
Slow Blow (T) = 250mA
13.75V 1.0A Continuous
3.15A Quick Blow
1.25A Quick Blow
D1-
D2+
D3
D4
+
AC
Input
Earth
Page: 127

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcx 26/sms

Table of Contents