P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L

13.7.5 Access Control

The following programming shows how to set up the Access Control facility if you are using it. For connection
details please see page: 138. This is not available on the PCX 26/SMS.
V i s u a l K e y p a d P r o g r a m m i n g P r o c e d u r e
Assign Keypads/Readers
Using the
and
KEYPADS/READERS?'
Press the
key
Address
Enter the address of the keypad/reader you wish to
assign. Press the
key
Type
Enter
: for Reader
Press the
key
Reader Is
Enter
: for Access Control
Press the
key
Enter the Lock Open Time (max: 250 seconds).
This is the time the door release is going to be active
when a valid tag's presented.
Press the
key.
Enter the Door Open Time (max: 250 seconds).
This is the time the door is allowed to be open before
triggering an alarm.
Press the
key.