1 3 . 1 8 E n g i n e e r R e s e t O p t i o n s
The Engineer Reset Options are used so that once an alarm has occurred; the PCX system can only be
reset by an engineer code, anti code or red care reset from the alarm receiving centre.
Option
Engineer Restore
of Intruder
Engineer Restore
of HU
Engineer Restore
of Tamper
Engineer Restore
of Soak
Engineer Restore
of Confirmed
Engineer Restore
of Faults
Anti Code Restore
V i s u a l K e y p a d P r o g r a m m i n g P r o c e d u r e

Engineer Reset Options

Using the
and
keys, scroll to 'ENGINEER
RESET OPTIONS?' Press the
Eng Reset Int
Enter
: for No
Enter
: for UK Intruder
Press the
key.
Eng Restore HU
Enter
: for No
Enter
: for Yes
Press the
key.
Repeat the above options for the restores: Tamper,
Soak, Confirmed, Faults and Anti Code Restore.
You will be returned to the Engineer Menu.
RINS871-3
Function
Following an intruder alarm, an engineer must reset the system before it can be used
again. Please select 'UK Intruder' to enable this, 'Secure Intruder' should not be
used. This will not interfere with the generation of an emergency alarm.
Following a Hold Up, Input HU or Duress alarm, an engineer must reset the system
before it can be used again. This will not interfere with the generation of a Fire or Gas
(emergency) alarm.
Following a Tamper alarm, an engineer must reset the system before it can be used
again. This will not interfere with the generation of an emergency alarm.
In the event of an input with the 'soak' attribute triggering whilst the system is armed,
the system must be reset by an engineer before it can be used again. This will not
interfere with the generation of an emergency alarm.
Following a confirmed alarm, an engineer must reset the system before it can be
used again.
If selected, an engineers code will only be able to reset the following faults:
STU/ATE telecom fail, Modem fail, STU/ATE single path fail, Telecom line fail,
Battery disconnect, Batt charge, Batt load, Excessive charge, Battery critical, Device
fail.
Enables the system to display an anti-code whilst awaiting an Engineer reset, which
can be used to generate a special reset code.
E N G I N E E R R E S E T O P T I O N S
key
P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L