C (Pcx-Access); A Ccess C Ontrol (Pcx-Access) - Pyronix 256 System Manual

Table of Contents

Advertisement

P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
1 7 . 1 4 A c c e s s C o n t r o l ( P C X - A C C E S S )
PLEASE NOTE THIS CANNOT BE USED ON THE PCX 26/SMS SYSTEM
The PCX system provides access control facilities integrated into the alarm system, incorporating the
following features:
Number of Doors
Reader Head
Lock Release
Tags
Lock Open
Door Open
Door Monitor
Local Alarm
Request to Exit
Power Supply
D1
D2
D3
D4
RS-485
D1
RS485 0V Supply
D2
RS485 +12V Supply
D3
RS485 'A' Data
D4
RS485 'B' Data
Reader Connections
0V
Black (0V)
13V
Red (+12V)
D-
Brown
D+
Blue
LED
Green
SDR
White
Fuse Values
F1
3.15A
F2
3.15A
Page: 138
1 per door station, max (dependant upon other control devices fitted):
PCX-256: 15
Fully sealed to IP66 for exterior use.
Suitable for any type, including car park barriers. Voltage or volt-free outputs
available, for 12V or 24V DC, or AC mechanisms.
Proximity tags shared with system operation. Max:
PCX-256: 500
Timer programmable individually 0 – 250 seconds.
Timer programmable individually 0 – 250 seconds.
Yes – may be integrated into alarm system.
Yes – changeover relay contacts.
Input for normally open push button.
Integrated with door station. Can power second station for two-way access.
1
2
4
8
16
BATT
ADDRESS
Outputs etc
0V
Lock 0V
13V
Lock +12V
NC
Lock Normally Closed
C
Lock Common
NO
Lock Normally Open
0V
Supply 0V
13V
Supply +12V
NC
Alarm Normally Closed
C
Alarm Common
NO
Alarm Normally Open
0V
RTE (Exit Button)
RTE
RTE (Exit Button)
0V
Door Mon.
Door Mon
Door Mon.
RINS871-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcx 26/sms

Table of Contents