Terminals Of The Pcx-Rox16R; Addressing The Pcx-Rox16R - Pyronix 256 System Manual

Table of Contents

Advertisement

P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L

17.12.3 Terminals of the PCX-ROX16R

RS-485 +12V Supply
K+
A
RS-485 'A' Data
B
RS-485 'B' Data
K–
RS-485 0V Supply

17.12.4 Addressing the PCX-ROX16R

ROXs are addressed using the DIP switches on the PCB. A maximum of 8 ROXs can be connected to a
PCX 256 system and 1 ROX to the PCX 26/SMS. The DIP switches operate as follows:
Switches should be On or Off as shown in the following table.
Page: 132
NC#
C#
NO#
T T
OFF
Address
1
00
OFF
01
ON
02
OFF
03
ON
04
OFF
05
ON
06
OFF
07
ON
PGM Relay Normally Closed Output
PGM Relay Common Output
PGM Relay Normally Open Output
Tamper Terminals
ON
8
4
2
1
Switch
2
4
8
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
ON
OFF
ON
ON
OFF
RINS871-3