Pyronix 256 System Manual page 151

Table of Contents

Advertisement

Type
Follow Input*
0035
See page: 81.
0036
Shunt Fault*
0037
Reset 1 (Viper Reset)
Reset 2 (Viper
0038
Arm/Disarm)
0039
PIR Latch 1
0040
PIR Latch 2
0041
Mains Good
0042
Detr Indn Enable*
0043
Follow Test
0044
Off During Test
0051
Telecom Line Fault
0052
AC Fail
0053
Battery Faults
0054
Low Volts
0055
Global Fault 1
0056
Global Fault 2
0057
German Relay*
0058
Guard Code Used
0059
Engineer Access
0060
Initialise Digi
0063
Test ATE/GSM*
0064
Test ATS
0066
ATE not used
A repeating block of output types should be noted:
0202
Hold Up A
0203
Intruder A
0204
Final Arm A
0207
Tamper A
0208
Duress A
0209
HU Device A
0213
Secure Intruder A
0214
Bell A
0216
Strobe A
0217
Omit At Rearm A
RINS871-3
P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
Active
When input triggers
See Shunt Inputs - Page: 55
At code entry to arm
At code entry to arm
Re-triggers whenever an additional partition is armed
When armed (and in Walk
Test)
This is the inverse polarity to PIR Latch 1
Output showing the mains is healthy
This output activates during walk test and also when a code is
entered to view indications – staying activated for the time for
which the indications are viewed.
New output for alternative bell test by activating SAB
New output for alternative bell test by activating SAB
When Line Fault signalled by
communicator
After pre-set time without
mains power
When battery disconnected or
load fail detected
At fault
Activates if fault occurs only
when system is armed (Faults:
Modem, Battery, Fuse, Line,
Mains)
Activates if fault occurs at any
time (Faults: Modem, Battery,
Fuse, Line, Mains)
When 'guard' code accepted
When entering Engineer Mode
At power up
Test signalling through
PSTN and GSM. Activates
when a test call is
sent.(used for specific
GSMs)
Test signalling through
PSTN and GSM. Activates
when a test call is sent.
Makes the ATE pin 5V.
As 0002 for Partition A / Arm Level A events only
As 0003 for Partition A / Arm Level A events only
As 0004 for Partition A / Arm Level A events only
As 0007 for Partition A / Arm Level A events only
As 0008 for Partition A / Arm Level A events only
As 0009 for Partition A / Arm Level A events only
As 0013 for Partition A / Arm Level A events only
As 0014 for Partition A / Arm Level A events only
As 0016 for Partition A / Arm Level A events only
As 0017 for Partition A / Arm Level A events only
Restore
procedure completed
Dependant upon programming
After 3 seconds
When disarmed
At alarm, or when disarmed
When fault clears
On restoration of mains
At next valid code entry
When fault clears
When all faults cleared
When all faults cleared
After 60 seconds
When leaving Engineer Mode
Live for 45 seconds only
When test completed
When test completed
Page: 151