Pyronix EURO 46 APP User Manual
Hide thumbs Also See for EURO 46 APP:

Advertisement

EURO 46 APP

User Manual

Connect to your
home or business
from anywhere in
the world.
Software version ≥2.1
RINS1840-2

Advertisement

Table of Contents
loading

Summary of Contents for Pyronix EURO 46 APP

  • Page 1: User Manual

    EURO 46 APP User Manual Connect to your home or business from anywhere in the world. Software version ≥2.1 RINS1840-2...
  • Page 2: Table Of Contents

    Master Manager menu: Wi-Fi Setup User Friendly Keyfobs User Automation Outputs Master Manager menu: Set Up App Data Operating the Euro 46 APP Panel Master Manager menu: Set Up App Data How to navigate through the menus/Button Operation Master Manager menu: SMS Phonebook...
  • Page 3: Two Way Wireless High Security

    Advanced technology preserves the battery life of each wireless device. The EURO 46 APP panel also informs you in advance of when a battery needs replacing, giving you enough time to change the battery in the specific device before it stops working. This key feature keeps your environment fully protected, unlike other conventional systems.
  • Page 4: User Friendly Keyfobs

    HU (Hold-Up / Panic alarms). Up to 32 wireless keyfobs can be added to your EURO 46 APP Panel. Each wireless keyfob has a unique ID, which can be reported to the ARC and HomeControl+ App. These are stored in the event log of the EURO 46 APP Panel individually. The keyfob also allows you to individually set or unset every area, giving you total control of your system.
  • Page 5: Operating The Euro 46 App Panel

    Setting/Unsetting Methods: There are four different methods that can be used for setting or unsetting your alarm: using the EURO 46 APP Panel keypad, using a proximity tag, a keyfob or the HomeControl+ App on your mobile (Android or iOS) device.
  • Page 6: How To Navigate Through The Menus/Button Operation

    How to navigate through the menus/Button Operation The Master Manager menu allows you to set up specific features by asking you a series of setup questions: No - Scrolls forwards in the main menu and sub-menus / returns you to the previous menu level once you have scrolled through all of the options.
  • Page 7: Chime Feature

    Chime Feature: HU Alarm from keypad: This feature can be set up by your installer and With the standard Euro Keypad, if you require a Hold-Up (HU) is most commonly enabled for doors using the alarm, press and hold both the 1 and 7 keys for 3 seconds and magnetic contact.
  • Page 8: Using The Keyfob - The Buttons

    If you have chosen to program one of the keyfob buttons as ‘Set Area’ , you can then opt to ‘quick set’ that area. When you press the button to set the area, the EURO 46 APP panel will begin to count down your exit time (depending on what exit mode has been programed by your engineer).
  • Page 9: Setting Your Euro 46 Panel

    Setting your Euro 46 APP panel There are four ways that you can set your system. Enter your user code and select any areas that are to be set, then press the  button as shown below: Euro 46 App...
  • Page 10: Unsetting Your Euro 46 Panel

    Unsetting your Euro 46 APP panel There are four ways that you can unset your system. Enter your user code and select any areas that are to be unset, then press the  button as shown below: Euro 46 App...
  • Page 11: Setting / Unsetting With The Tag Reader

    Setting / Unsetting with the Tag Reader (optional extras) It is possible to set and unset your system using a tag wherever a reader is installed. Setting (See diagram to the right): External Tag Reader LEDs (shown for system set) Present a valid tag to the reader.
  • Page 12: The Wireless Arming Station

    The Wireless Arming Station (optional extra) The wireless arming station mirrors the control panel keypad so as to control it from another room. You will notice that it has the same LEDs and symbols, and the same layout - it even has the same tag reader functionality. In addition to these features, it has direct output control, with 4 dedicated LEDs to indicate the status of your outputs (ON or OFF).
  • Page 13: Sms Commands

    (GPRS with third party SIM only) If you have the GPRS version of the EURO 46 APP panel you can send SMS text commands via your mobile phone. NOTE: All SMS commands must start with a valid user code and are not case sensitive unless the utilised outputs are activated.
  • Page 14 Checking the system status vis SMS text command Example SMS command send: Description: Example SMS command response: 123456 Status 123456 = User Code. Status Area A Unset No Faults Area B Unset No Faults Area C Unset No Faults Area D Unset No Faults Operating the User Automation Outputs via SMS text commands Example SMS command send: Description:...
  • Page 15: Master Manager Menu Options

    Master Manager menu options Set Date & Time Programs the date and time and enables the summer-time automatic adjustment. Operate User Outputs Activates/deactivates user automation outputs that are used to remotely activate devices, such as electronic gates & lights. Omit Inputs Disables any sensor (input) on the system for the current setting period.
  • Page 16: Entering The Master Manager Menu

    Entering the Master Manager menu Euro 46 App Enter Your Code SET DATE & TIME? Time 02:11 c [******] Default Master Code is: 2222 We recommend that this is changed Master Manager menu: Date and Time NOTE: Date and Time are set automatically on most networks.
  • Page 17: Master Manager Menu: Operate User Automation Outputs

    Master Manager menu: Operate User Automation Outputs OPERATE USER Select Output Output On OUTPUTS? [01] Select User Automation Output: [0] Output 1 [30] Output 30 OMIT INPUTS? Master Manager menu: Omit Inputs OMIT INPUTS Omit Day Al [--] Omit Day Al [--] Input 01 Select Inputs: [0 - 46] CHANGE CODES?
  • Page 18: Master Manager Menu: Change Codes

    Master Manager menu: Change Codes - configure user codes USE THIS OPTION BELOW TO CHANGE ANY USER CODES (IF USER CODES HAVE BEEN SETUP) USE THIS OPTION BELOW TO CHANGE THE DEFAULT MASTER MANAGER CODE...
  • Page 19 Change Codes: Configure Proximity Tags Flexi Set: If selected as ‘Yes’ you will be able to choose the area you wish to set after you have entered your user code or presented a valid tag. If selected as ‘No’ , the control panel will automatically set all areas that the panel/code is assigned to.
  • Page 20 Change Codes: Learn / Configure Keyfobs (only available on systems with a wireless ZEM) Press C Key to DELETE code Add New User? Empty [03] Enter User Code User Name Press and Hold ANY button for 5 seconds Select Button Button Action [1] If Set Area User Areas...
  • Page 21: Master Manager Menu: Review Logs

    Master Manager menu: Review Logs This menu can be used to access the full panel and access logs - in order to check the history of events that have transpired on your alarm system. The HomeContol+ App can also be used to see the latest system events. REVIEW LOG? Panel Log? 01/01 00:11:44...
  • Page 22: Master Manager Menu: Wi-Fi Setup

    Master Manager menu: Set Up App Data (if enabled by engineer) Security Level: Normal SET UP APP Use App System ID Cloud Password: Security Level DATA? AAAAAAAA Normal Use App: Security: [0] No [0] Normal [1] Yes [1] High App Password: Alwys Poll Cloud NOTE: It is highly recommended that ‘Always Poll Cloud’...
  • Page 23: Master Manager Menu: Set Up App Data

    Master Manager menu: Set Up App Data (if enabled by engineer) Security Level: High THIRD PARTY SIM CARDS ONLY: Password key to be sent to your mobile phone so that ONLY YOU know the App password. UK numbers can be entered with or without an international dialling code (e.g.
  • Page 24 Master Manager menu: Wi-Fi Setup (WiFi module available in future) NOTE: 32 Characters MAX for SSID and password entry. Do not enter spaces at the beginning or end.
  • Page 25: Master Manager Menu: Sms Phonebook

    Master Manager menu: SMS Phonebook (Third party SIM cards only) NOTE: UK numbers can be entered with or without an international dialling code (e.g. +44). If you need to enter an international dialling code to send the key to a foreign SIM card –use the ...
  • Page 26: Master Manager Menu: Allow Engineer Menu

    Master Manager menu: Allow Engineer Menu Master Manager menu: Block Remote Set BLOCK REMOTE Block Remote Set SET? This function will block any attempt made to set or unset via the UDL software if enabled. Block UDL remote set: [0] No [1] Yes BLOCK UDL?
  • Page 27: Master Manager Menu: Block Udl

    Master Manager menu: Block UDL If enabled, this function will block any attempt made to dial into the control panel to upload and down- load information. Master Manager menu: System Sounds Demo...
  • Page 28: Master Manager Menu: Exit Master Manager Menu

    Master Manager menu: Exit Master Manager menu Engineer Contacts / Installation Record Table Alarm Installation Company: Date of Installation: Site Reference: Engineer Name: Engineer Contact Number: Installed to Grade 2: Yes / No Installed to Grade 3: Yes / No Environmental Class: Other Comments:...
  • Page 29: Input Tables

    Input tables Wired or Wireless Input Name Input Areas Description Wired only Input Name Input Areas Description Inputs Inputs 09 (ZEM 0) 10 (ZEM 0) 11 (ZEM 0) 12 (ZEM 0) 13 (ZEM 0) 14 (ZEM 0) 15 (ZEM 0) 16 (ZEM 0) 17 (ZEM 1) 18 (ZEM 1)
  • Page 30: User Tables

    User Tables User Name Code/Tag/ User Name Code/Tag/ User Name Code/Tag/ Keyfob Keyfob Keyfob...
  • Page 31: Outputs Table

    Outputs Table Wired Latched Name & Action Wired Latched Name & Action ZEM Outputs Latched Name & Action Outputs (wired/wireless) / Timed Outputs / Timed / Timed BELL O/P User Output 15 ZEM-0 Output 1 STB O/P (strobe) User Output 16 ZEM-0 Output 2 PGM O/P User Output 17...
  • Page 32: Product Information

    Environmental Class II Pyronix Guarantee At Pyronix Limited we are proud of our products and believe that we ensure both suitable materials and the utmost skill and care are used in manufacturing them. We are confident in the abilities of the installers and distributors to whom we sell our products, and the high standards that they employ to ensure that Pyronix products are delivered to you in the same condition as they left us.

Table of Contents