Appendix B: Input Types - Pyronix 256 System Manual

Table of Contents

Advertisement

Fault
Description
Battery Fuse (F4) failed,
BATTERY
OR Battery not present,
FAULT xxx
OR Battery volts low
BAT LOAD
Battery Load Test has failed
FAIL
Battery being disconnected
BATTERY
CRITICAL
Mains supply failed
MAINS FAIL
xxx
Fuse identified failed,
OR Output protected by fuse
FUSE x FAULT
drawing excessive current
Power supply volts low
LOW VOLTS
xxx
Fault
Description
Engineer
Access to Engineer menu
Access Denied
NOT possible, as system is
not fully disarmed.
Check Failed
Input in fault on attempting to
Input xxx
exit Engineer mode.
Error input
A input has been programmed
part'ns not
to a partition for which no
accessible
arming point is valid to disarm.
Error some
Arming points have been
part'ns cannot
programmed such that it is
be disarmed
possible to arm a partition, but
not disarm it.
RINS871-3
P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
POWER SUPPLY PROBLEMS
Solution
Note: This indication should be expected
during recharge after a mains failure.
Only displays if option selected. Battery uncharged or
capacity below specification may need replacing.
Protects battery from deep discharge damage during
extended mains failure.
Note: System is now powered down!
System detects mains frequency out of
specification, as well as voltage. Note: 'AC FAIL'
timer operative
FUSE 1: PGMs
FUSE 2: BELL
FUSE 3: AUX
FUSE 4: BUS
FUSE 5: BATTERY
Battery volts below normal 'battery fault' level during
mains failure
ENGINEER INDICATIONS
Solution
Ensure that ALL partitions are disarmed, using a suitable
user codes / tags at appropriate keypads / readers.
Applies to 24-hour tamper, or other input types that
would generate an alarm condition if the system were
returned to disarmed mode.
Also applies to tamper fault on other input types.
Check for fault on input, or omit in programming.
It would therefore be impossible to fully disarm the
system after a tamper alarm on that input.
Programming must be adjusted before exiting Engineer
mode.
Programming must be adjusted before exiting Engineer
mode.
Page: 145