13.23.3 Programming SMS Texts

The PCX system also has the facility of sending an SMS to a mobile phone when an alarm has occurred.
This facility can be programmed using the content type the protocol Contact ID uses.
Content Types
01
Arm
02
Disarm
03
Special Disarm
04
Arm Fail
05
Alarm
06
First alarm
07
Alarm Silenced
08
Confirmed
09
LoTechFault
10
HiTechFault
11
Tech Info
12
Manager Info
13
Engineer Info
14
*AccessC Alarm
15
*AccessC Info
16
*AccessC Ref
17
*SL SwitchOn
18
*SL SwitchOff
19
*SL OtherOn
20
*SL OtherOff
21
*Sub-partitions Set
22
*Sub-partitions
Unset
23
*Sub-partitions
Alarm
24
Input Omitted
25
Input Restore
26
Test Call
27
Mains fail
28
Emergency input
29
Emergency
Restore
30
Tamper input
31
First Tamper input
32
Tamp Input
Restore
*Not available in the PCX 26/SMS
RINS871-3
P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
All arm events (by area/level & user name)
All disarm events (by area/level & user name)
Disarm events initiated by codes 15 to 20 only
Attempt to arm the system failed
All alarm events (by partition, level and type) inc. code guess (excludes
tampers and emergency input types)
First to alarm event (for each input) only
Any alarm/fault silenced (by partition)
Sequentially confirmed alarm
Telecom Line restore (STU/ATE or DigiModem)
Low volts, Battery fault/OK, Fuse failure, RS-485 or Device Failure
System restart, Over current, Logs cleared
Code changed / deleted
Engineer accessing system, and leaving
Access Control door forced or left open
Access Control tag at Reader
Access refused (invalid code)
+Switcher input active
+Switcher input restored
+Other input active
+Other input restored
Arming events for sub-partitions
Disarming events for sub-partitions
Alarm event in a sub-partition
Input omitted at rearm.
Restore of type 05
Do not Use
Mains fail/restore
Fire, Gas, HU, 2-key HU, Duress Code used
Restore of Fire, Gas, HU.
Tamper, Day alarm, and Trouble input types. Tamper on input, case tamper
and SAB tamper.
First to alarm of tamper input.
Restore of a tamper.
+ - Signalled ONLY for inputs with 'Special Logged'
attribute.