V i s u a l K e y p a d P r o g r a m m i n g P r o c e d u r e
Intelligent Arm
Using the
and
ARM?' Press the
key
Intelligent
Enter
: for No
Enter
: for Yes
Press the
key.
Use the numeric keys to select the input(s) that will
cause Intelligent Arming to occur. Press the
You will be returned to the Engineer Menu.
1 3 . 1 7 S i t e O p t i o n s
A full range of site options is available to tailor the operation of the system.

13.17.1 Site Option Types

Option
Arm With Fault
Arm With Tamper+
Arm With ATS
Fault
Arm With Part
TFault*
Arm Fail = Alarm
Do Bat Load Test
Part Misoperation*
Strobe Confirm
Re-Arm Omits
RINS871-3
I N T E L L I G E N T A R M
keys, scroll to 'INTELLIGENT
Function
If 'YES': Allows arming with the following faults active: Device fail, Mains fail, Battery
faults, Fuse faults, SMS failure, STU/ATE sirens 1&2, STU/ATE Strobe faults.
If 'YES': Allows arming with the following faults active: Case tamper and System
tampers.
If 'YES': Allows setting with the following faults active: Telecom line fail, Modem
failed, STU/ATE line fault, STU/ATE one path fail, Digi dial fail, STU/ATE comms fail.
If 'YES': Allows a sub-partition to be armed if a relevant mains, battery, telecom line,
or other system fault is present.
If 'YES' = A graduated alarm will be generated when 'Arm Fail' timer expires (see
Change Timers), if exit procedure is still incomplete. Arm fail output will trigger.
If 'NO' = Exit time will continue until the Exit route is clear.
If 'YES': Programmes the system to perform a full load test of the battery at 7.00am
each day.
If 'YES' Allows a Misoperation (Abort) signal to be generated without the entry of a
valid code into the system when sub-partition is operated after an alarm.
If 'YES': A 'STROBE ANY' output will be activated for 5 seconds as the system arms.
Use with care, in view of potential security risk.
If 'YES': At rearm at the end of the confirmation time, this function will force an input
(not a system tamper) causing an unconfirmed alarm to be omitted, whether it's still in
fault or not.