Output Types - Pyronix PCX 78 Installation Manual

Table of Contents

Advertisement

Number
Input
types
20
Keyswitch
Latched*
21
Entry
Shock
22
Line Fault
23
Keyswitch
Pulsed*
39
CCTV
41
Patrol /
Keybox
42
Medical
43
Entry
Delay 2$
45
Silent
Medical
By default, all inputs are set to 'unused'.
# These inputs cannot be bypassed.
* Use of these inputs will make the system unable to comply with EN50131-1 Security Grade 2.
$ Ensure that these inputs are used on an entry/exit route

Output Types

No.
Output
Type
0000
Not Used
0001
Fire
0002
PA Any
0003
Burglary Any
82
PCX Installation Guide
Operation
Accepts input from keyswitch (or equivalent) to arm/disarm the area assigned to it.
Arming includes normal exit time, etc. Requires latching switch action. Normal operation is open
circuit to arm the system, and close circuit to disarm the system.
Active when system armed: This input type is advised to be used in conjunction with an Entry Delay
input. The Entry Delay input is a door contact on the initial entry door, and the Entry Shock input is a
non-latching shock sensor fitted to the door frame in the vicinity of the lock. If the door is forced a
Burglary alarm will be generated immediately instead.
Active when fail. This input type is used to detect external transmission equipment line fail (output). If
activated it will give a line fault alarm, and will signal telecom line fault on expiry of line fault timer. It
can be used in conjunction with CCTV input (type 39)
Accepts input from keyswitch to arm/disarm the area(s) assigned to it. Requires momentary action
switch to toggle arm/disarm state.
Note that Grade 1 operation only allows arming from the push button, but requires means to abort
arming (not to disarm)
Active at all times: No audible alarm or communicator response.
The CCTV input should be connected to an external detector located next to a CCTV camera. An
output can be programmed to follow this input and the output should be connected to a CCTV
recording, transmission or other device. An input programmed as "Line Fault" (input type 22) should
also be connected to an output of the CCTV transmission Device. If the CCTV transmission line has
been cut or missing the 'Line Fault' input will activate. Following this, at each activation of the CCTV
input the panel will signal CID events for 'Silent Burglary' and Line Fault. No audible alarm will be
created. If the Line Fault is not active it will just log the activations of the CCTV input into the event
log.
This input type will work similarly to a switcher input, it does not trigger an alarm but will report
Contact ID event 250 and is also a useful input type when an output is required to follow the 'Keybox'
type input.
This is a 24 Hrs type input it will activate the external sounder and report a Contact ID event 100.
Any input programmed as Entry Delay 2 will act as input type 07, but the associated entry timer will
use Entry Timer 2, rather than Entry Timer 1.
Active at all times. Audible Response: None. Reports a Contact ID event 100.
Active
At fire alarm activation
At personal attack activation
At burglary alarm from any area
Restore
When a valid code is entered
When a valid code is entered
At first valid code entry
102017852 - V01