Pyronix EURO 46 V10 User Manual
Hide thumbs Also See for EURO 46 V10:

Advertisement

EURO 46 V10
User Manual
PD6662:2010+IA501:2015
EN50131-1:2008+A1:2009
EN50131-3:2009
Security Grade (SG) 3 - Large
Security Grade (SG) 2 - Small
Environmental Class (EC) II
Software Version >10
RINS1943-1

Advertisement

Table of Contents
loading

Summary of Contents for Pyronix EURO 46 V10

  • Page 1 EURO 46 V10 User Manual PD6662:2010+IA501:2015 EN50131-1:2008+A1:2009 EN50131-3:2009 Security Grade (SG) 3 - Large Security Grade (SG) 2 - Small Environmental Class (EC) II Software Version >10 RINS1943-1...
  • Page 2: Table Of Contents

    Block UDL Set Block UDL System Sounds Demo Using the HomeControl+ App Adding a Panel to the App Connecting to a Panel Setting and Un-setting the System Sensors, Controls and History Notifications The Main User Interface EURO 46 V10 User Manual...
  • Page 3 Engineer Contact Details and Tables Engineer Information Certification Input Table Input Notes Users Table User Notes HomeControl+ App Icons Disclaimer EURO 46 V10 User Manual...
  • Page 4 EURO 46 V10 User Manual...
  • Page 5: Introduction

    This alarm system has 6 areas which may be set up in the following way: Area A: Full set of the house Area B: Downstairs set. Upstairs unset. Area C: Garage set. Rest of house unset. Your engineer will be able to design the system according to your needs. EURO 46 V10 User Manual...
  • Page 6: Homecontrol+ App

    Control appliances such as lights, garage doors, gates and blinds All using an encrypted, highly secure system, for extra peace AES-256 Encryption of mind that your family and home is safe and secure 9:41 AM 100% 10:09 EURO 46 V10 User Manual...
  • Page 7: Setting Devices

    Red = Set Present the tag again within 10 seconds and the system will set or unset. The system will then set depending on the type of exit mode programmed (Final Door, Timed or Push to set), EURO 46 V10 User Manual...
  • Page 8: Wireless Arming Stations

    Once illuminated, it signifies that the output has triggered. Press the key again to deactivate the output. For information on how these may have been programmed, please speak to your engineer. Check out our wireless range at www.pyronix.co.uk EURO 46 V10 User Manual...
  • Page 9: Setting The System

    Select the area or areas you wish to unset then press [*******] PLEASE NOTE: If ‘flexi-unset’ is disabled then the system will automatically unset the levels or areas set, once a valid user code or tag is presented. EURO 46 Time 10:09 c EURO 46 V10 User Manual...
  • Page 10: After An Alarm

    The alarm symbol will flash indicating there has been an alarm activation and the keypad will display which input has activated. Alarm silenced Pantry Press h to reset the system. EURO 46 Time 10:09 c EURO 46 V10 User Manual...
  • Page 11: Using A Proximity Reader

    Please contact your engineer for more information on this feature. PLEASE NOTE: Both the internal and external tag readers use the same proximity tags that are used to set and unset on the keypad of the system. EURO 46 V10 User Manual...
  • Page 12: Anti-Code / Engineer Restore

    Alternatively, the engineer may have just enabled ‘Engineer Restores’ and not anti-code. In this instance the keypad will just display ‘Restore Required’. In this scenario, please contact your installation company and explain the situation. Restore Required EURO 46 V10 User Manual...
  • Page 13: Fault Indications / Unable To Set

    Press a. After 10 Omit Day Al [01] seconds the exit time continues. PLEASE NOTE: Inputs have to be programmed as ‘omittable’ by your engineer for this feature to operate. EURO 46 V10 User Manual...
  • Page 14: Keypad Hold Up / Panic Alarm

    7 (the length of time they need to be pressed is EURO 46 programmed by your engineer). Time 10:09 c A ‘Hold Up’ alarm will be generated. PLEASE NOTE: The ‘Hold Up’ facility needs to be enabled by your engineer (either silent or full alarm). EURO 46 V10 User Manual...
  • Page 15: Master Manager Menu

    Press b or h keys to scroll through until ‘EXIT MANAGER MODE’ is displayed. Press f. EXIT MASTER Or to exit the menu, when a main item is displayed MENU? (capital letters) press a . EURO 46 V10 User Manual...
  • Page 16: Menu Options

    Day (1-31) [01] Enter the Hours. Press f. Hours (0-23) [10] Enter the Minutes. Minutes (0-59) Press f. [09] DST (Daylight Saving Time) adjust. Use b and d to select then press f. DST adjust? EURO 46 V10 User Manual...
  • Page 17: Operate User Outputs

    Press b or h to scroll to ‘EDIT USERS?’. Press EDIT USERS? To add a new code or tag press f. Press h to delete or change a user code (see the next section for details). Add New User? EURO 46 V10 User Manual...
  • Page 18 Enter the user name and press f. User Name Repeat to add more users. PLEASE NOTE: For instructions on adding a key fob please refer to the manual provided with the product. EURO 46 V10 User Manual...
  • Page 19: Edit Users (Deleting And Changing Users)

    To edit the Master Manager Code, press f. Enter the new code or present a tag. Press f. Change Master Refer to the section ‘Adding New Users’ for the options Manager Code? which will follow the code change. EURO 46 V10 User Manual...
  • Page 20: Event Log

    01/01 10:09:26 User Added Press the c key on any log entry to show more information (such as which input activated, or which user set the system etc.). Daniel EURO 46 V10 User Manual...
  • Page 21: Set Up App Data

    Set up App Data Follow the information below to connect the alarm system to the Pyronix Cloud. PLEASE NOTE: This menu will only be visible with a HomeControl+ compatible module installed. Press b or h to scroll to ‘SET UP APP DATA’. Press...
  • Page 22: Module Set Up

    The connection of the module would typically be set up by the engineer on installation and if that has been done it is not recommended that the existing programming in this menu be changed. Please refer to the ‘Communications Guide’ for more details on this menu. EURO 46 V10 User Manual...
  • Page 23: Sms Phonebook

    ‘Walk Test Completed’ will be displayed. Walk Test Input 01 Walk Test Individual Inputs Press b or d to scroll through the different inputs and press f to walk test that input. Walk Test Input [01] EURO 46 V10 User Manual...
  • Page 24: Siren Test

    UDL software. Should you wish to block this access, you can enable this function. Press the b or h keys to scroll to ‘BLOCK UDL SET’. Press f. BLOCK UDL SET? Press b or d to select either ‘Yes’ or ‘No’. Press Block UDL Set EURO 46 V10 User Manual...
  • Page 25: Block Udl

    Use the b and h keys to scroll to ‘SYSTEM SOUNDS DEMO’. Press the f key. SYSTEM SOUNDS DEMO? Press b or d to scroll through the different system sounds. Press f to exit. Sound to Play No Sound [00] EURO 46 V10 User Manual...
  • Page 26: Using The Homecontrol+ App

    Enter a valid user code and If the user code, or ‘App to connect to. the ‘App Password’ then press Password’ is wrong, the below ’Log In’. will be shown and you will need to re-enter the information. EURO 46 V10 User Manual...
  • Page 27: Setting And Un-Setting The System

    PLEASE NOTE: All areas that padlock will be shown. To unset, bell symbol. This will then show show a green open padlock are tap the area that is set. the open padlock symbol and unset. the area is unset. EURO 46 V10 User Manual...
  • Page 28: Sensors, Controls And History

    Notifications Notifications can be viewed in your HomeControl+ App by touching the envelope icon. The icon will change to a ‘green envelope’ when a new notification is available. EURO 46 V10 User Manual...
  • Page 29: The Main User Interface

    The Main User Interface Edit an existing Add a new System settings Remove system Notifications system system 9:41 AM 100% 10:09 EURO 46 V10 User Manual...
  • Page 30: Engineer Contact Details And Tables

    Immunity requirements for components of fire, intruder and EN 50130-4:2011 +A1:2014 social Wireless Alarm Systems EN 60950-1:2006 +A12:2012 Information technology equipment. Safety. General requirements Grade 2. Interconnections for equipment using radio frequency EN 50131-5-3:2005+ A1:2008 techniques EURO 46 V10 User Manual...
  • Page 31 Check with your Local Authority or retailer for recycling advice in your country. When disposing of the product the batteries must be removed and disposed of separately in accordance with the local regulations. EURO 46 V10 User Manual...
  • Page 32: Input Table

    Input Table Input No. Input Name Input Areas Description EURO 46 V10 User Manual...
  • Page 33 Input No. Input Name Input Areas Description EURO 46 V10 User Manual...
  • Page 34: Input Notes

    Input No. Input Name Input Areas Description Input Notes EURO 46 V10 User Manual...
  • Page 35: Users Table

    Users Table Code No. Code/Tag/Fob Code Areas Code Name Master EURO 46 V10 User Manual...
  • Page 36 Code No. Code/Tag/Fob Code Areas Code Name EURO 46 V10 User Manual...
  • Page 37: User Notes

    Code No. Code/Tag/Fob Code Areas Code Name User Notes EURO 46 V10 User Manual...
  • Page 38: Homecontrol+ App Icons

    Add system Detector fault New notification Area in alarm Notifications Search Supervision fault Output is switched ‘off’ or option set to ‘no’ Refresh Output is switched ‘on’ or option set to ‘yes’ Disconnect from system EURO 46 V10 User Manual...
  • Page 39: Disclaimer

    Electronic messages and SMS messages are carried by the POTS/SMS Server operator by means of networks and transmission facilities over which Pyronix Limited (Pyronix) has no control. Pyronix shall therefore not be responsible for the POTS/SMS Server operator’s service level or the POTS/SMS Server operator’s network failures.

Table of Contents