P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
Type
0018
Unconfirmed Any
0019
Can All Arm*
0020
Exit Starts All*
NOTE: For 'exit starts' to be entered in system logs, the site option 'Confirmed when...' must be
set to 'exit start'
0021
Exit Starts Any
0022
Final Arm Any
0023
Strobe Set Fail
0025
Keyswitch unset
Set with Omit (Not on
0026
PCX 256)
0031
Entry*
0032
Exit*
0033
Entry/Exit
0034
Lights
Follow Input*
0035
See page: 81.
0036
Shunt Fault*
0037
Reset 1 (Viper Reset)
Reset 2 (Viper
0038
Arm/Disarm)
0039
PIR Latch 1
0040
PIR Latch 2
0041
Mains Good
0042
Detr Indn Enable*
0043
Follow Test
0044
Off During Test
0051
Telecom Line Fault
0052
AC Fail
0053
Battery Faults
0054
Low Volts
0055
Global Fault 1
0056
Global Fault 2
0057
German Relay*
0058
Guard Code Used
Page: 76
Active
Any intruder or Tamper alarm
If all inputs and technical faults
in system are clear. Also once
entry time has started
At start of exit time to arm
LAST partition
When exit time starts to arm
FIRST partition
When FIRST partition is armed
Works similar to output 016, but also fires if the set fail timer
expires.
This output turns on for 5 seconds when the system is disarmed
via a keyswitch input (either pulsed or latched keyswitch)
Activates when inputs are omitted on an arming mode
Live during any exit time
Live during any entry time
Live during any entry or exit time
When exit or entry timer starts
When input triggers
See Shunt Inputs - Page: 55
At code entry to arm
At code entry to arm
Re-triggers whenever an additional partition is armed
When armed (and in Walk
Test)
This is the inverse polarity to PIR Latch 1
Output showing the mains is healthy
This output activates during walk test and also when a code is
entered to view indications – staying activated for the time for
which the indications are viewed.
New output for alternative bell test by activating SAB
New output for alternative bell test by activating SAB
When Line Fault signalled by
communicator
After pre-set time without
mains power
When battery disconnected or
load fail detected
At fault
Activates if fault occurs only
when system is armed (Faults:
Modem, Battery, Fuse, Line,
Mains)
Activates if fault occurs at any
time (Faults: Modem, Battery,
Fuse, Line, Mains)
When 'guard' code accepted
Restore
At code entry to silence
If fault exists, and after final
arm
At code entry to disarm FIRST
partition (i.e. no longer fully
armed)
At code entry to disarm LAST
partition
At code entry to disarm LAST
partition
20 seconds after arm/disarm
procedure completed
Dependant upon programming
After 3 seconds
When disarmed
At alarm, or when disarmed
When fault clears
On restoration of mains
At next valid code entry
When fault clears
When all faults cleared
When all faults cleared
After 60 seconds
RINS871-3