PCX 256 PROGRAMMING MANUAL
5 . 1 5 C h a n g e O u t p u t s
The output types below may be programmed to any of the systems PGMs (Programmable
Outputs). Also the function 'Change Outputs' is where you install and initialise any Remote Output
Expanders you have installed to the system, this is done under the 'ROX Module PGMs'. Please
note that the PGMs must be used within their rated capacity.
NOTE: The PGM Outputs CANNOT be inverted. Only the ATE pins can (See 'Invert ATE
Outputs in 'Site Options' page: 47)

5.15.1 PGM Output Types

Type
0000
Not Used
0001
Fire
0002
Hold Up Any
0003
Intruder Any
0004
Final Arm All
Misoperation Any
0005
(Abort)
0006
Confirmed Any
0007
Tamper Any
0008
Duress
0009
HU Device Any
0010
Gas
0011
Arm Fail
0012
Entry Deviation
Secure Intruder
0013
Any
0014
Bell Any
0016
Strobe Any
0017
Omit Rearm Any
0018
Unconfirmed Any
0019
Can All Arm
Page: 38
Defaults
Active
ATE 1
At alarm
DIGI 1
At a HU or Duress alarm
(This includes keypad HU)
At alarm, while system is
disarmed
When ALL partitions are
armed.
When system is silenced
after any 'intruder' output is
triggered
When further input active in
ATE 7
any partition after 'intruder'
DIGI 7
alarm
ATE 6
Any tamper alarm
DIGI 12
At a Duress alarm (i.e. from
a keypad)
At alarm on a HU input only
ATE 2
(This doesn't include the
DIGI 2
keypad HU)
At alarm
Pre-set time after start of exit
time, if exit procedure is not
complete
When deviation from entry
route occurs, during entry
time
At alarm, after exit time
started, until disarm
PGM 5
When alarm live
PGM 4
When alarm live
At rearm at end of confirm
ATE 5
time if an input in fault is
DIGI 5
isolated
ATE 3
Any intruder or Tamper
alarm
DIGI 3
If all inputs and technical
faults in system are clear.
Restore
When a valid code is
entered
When a valid code is
entered
At first valid code entry
At code entry to disarm
After 2 minutes
At next code entry
At code entry to silence
When a valid code is
entered
When a valid code is
entered
When a valid code is
entered
At code entry to rearm
At code entry to disarm
At first valid code entry
When alarm silenced or
when siren timer expires
When alarm silenced or
when strobe timer expires
When system disarmed
At code entry to silence
If fault exists, and after final
arm
RINS868-6