Ate Inputs Page - Pyronix 256 System Manual

Table of Contents

Advertisement

P C X S M S A N D P C X 2 5 6 S Y S T E M M A N U A L
Use Level Arm*
Confirmed When
AutoSet Force*
Restrict PIN Use
Invert ATE O/Ps
Common Exit
Mode*
Flexi Unset
2 Key HU
ATE Inputs
* NOT AVAILABLE ON PCX 26/SMS
V i s u a l K e y p a d P r o g r a m m i n g P r o c e d u r e
Site Options
Using the
and
OPTIONS?' Press the
Arm with Fault
Enter
: for No
Enter
: for Yes
Press the
key. Repeat for all other options until:
2 Key HU
Enter
: for ATE Enter
Enter
: for Relay Enter
Press the
key. Repeat for ATE Inputs.
Page: 84
If 'YES': The system becomes a 'level arm' (Having one partition set only at any one
time, e.g. part sets). If 'NO': The system becomes a 'partition' system (setting more
than once area at a time)
Final Arm: Confirmed signal only available after the system is armed.
Exit Starts: Confirmed signal only available after the exit time has started.
Note: 'Exit Starts' must be selected in order for it to be entered in the logs.
If 'YES' when autoset is in use (this is only available in the ARM software) the panel
will still set even if an input is open at the time.
If 'YES' the system prevents a pin code being entered on the Entry Time, but allows
the system to be silenced once in alarm.
If 'YES': 'Positive Removed' If 'NO': 'Positive Applied'
If set to 'YES', this will automatically select the 'highest' exit mode for all partitions.
(0 = Timed, 1 = Final Door, 2 = Timed/Final Door, 3 = PTS).
For example, if Partition C is selected as Final Door and the rest of the partitions are
selected as Timed, then because Final Door is 'higher' than Timed (Final door is 1
and Timed is 0 in the programming), all partitions will be set to Final Door.
If set to 'NO' the Exit Modes will be individually programmable to each partition.
If set to 'YES', this will allow all codes with Flexi-Arm attribute enabled to pick and
choose which partitions to arm/disarm during entry time.
Selects whether the '2 key HU' function at the keypad is live, and if so, whether
signalled only, audible only or both. If 'YES': The
simultaneously, will generate a Duress Alarm.
Permits selection of inputs on 'plug on' communicator to suit 'STU' (including Red
Care Reset), 'DigiCom' (including Telback), 'Relay Interface Monitoring' or 'Not
Used'.Note: This option must be set to 'STU' or 'Digi' in order for Line Fault, etc.
monitoring to function.
S I T E O P T I O N S
keys, scroll to 'SITE
key
: for Digi
: for None
and
keys, pressed
RINS871-3