Pyronix 256 System Manual page 47

Table of Contents

Advertisement

V i s u a l K e y p a d P r o g r a m m i n g P r o c e d u r e
Choose Mode
Using the
and
keys, scroll to 'CHOOSE
MODE?'
Press the
key
The End of Line Range
(NOT AVAILABLE IN PCX 26/SMS)
Enter
: for 1K Range
Enter
: for 2K2 Range
Enter
: for 4K7 Range
Press the
key
NOTE: ONLY 4K7 RESISTORS CAN BE USED
UNTIL FURTHER NOTICE
The End of Line Mode
Enter
: for SEOL (Single End of Line)
Enter
: for DEOL (Double End of Line)
Press the
key
The Input Response
Select the required input response – using
(100ms) all the way to
This should be left at default (400ms).
Press the
key.
Input XDF
Enter
: for Dyn Not Used
Enter
: for Safe
Enter
: for Normal
NOTE: DO NOT CHANGE THIS SETTING
Press the
key
You will be returned to the Engineer Menu.