Configuring Hot Links

516
G8264CS Application Guide for ENOS 8.4
A port that is a member of the Master interface cannot be a member of the 
Backup interface. A port that is a member of one Hot Links trigger cannot be a 
member of another Hot Links trigger.
An individual port that is configured as a Hot Link interface cannot be a 
member of a LAG.
Spanning Tree Protocol must be disabled on Hot Links ports. For instance, if Hot 
Links ports 1 and 2 belong to STGs 1 and 23, use the following commands to 
disable the STGs:
RS 8264CS(config)# no span stp 1 enable
RS 8264CS(config)# no span stp 23 enable
Use the following commands to configure Hot Links. 
RS 8264CS(config)# [no] hotlinks bpdu
RS 8264CS(config)# [no] hotlinks enable
RS 8264CS(config)# [no] hotlinks fdb-update   (Enable or disable Hot Links FDB update)
RS 8264CS(config)# hotlinks fdb-update-rate   (Configure FDB update rate in packets per 
second)
RS 8264CS(config)# hotlinks trigger 1 enable   (Enable Hot Links Trigger 1)
RS 8264CS(config)# hotlinks trigger 1 master port 1 (Add port to Master interface)
RS 8264CS(config)# hotlinks trigger 1 backup port 2 (Add port to Backup interface)
RS 8264CS(config)# hotlinks enable
  (Enable or disable Hot Links BPDU flood)
  (Enable or disable Hot Links globally)
(Turn on Hot Links)