Configuration Guidelines

Configuring Hot Links

© Copyright Lenovo 2017
The following configuration guidelines apply to Hot links:
Only external ports can be configured as Hot Links.
When Hot Links is turned on, MSTP, RSTP, and PVRST must be turned off. 
A port that is a member of the Master interface cannot be a member of the 
Backup interface. A port that is a member of one Hot Links trigger cannot be a 
member of another Hot Links trigger.
An individual port that is configured as a Hot Link interface cannot be a 
member of a LAG.
Use the following commands to configure Hot Links.  
CN 4093(config)# hotlinks trigger 1 enable     (Enable Hot Links Trigger 1)
CN 4093(config)# hotlinks trigger 1 master port 38 (Add port to Master interface)
CN 4093(config)# hotlinks trigger 1 backup port 39   (Add port to Backup interface)
CN 4093(config)# hotlinks enable
(Turn on Hot Links)