Figure 17. VLAG Application with Multiple Layers
Wherever ports from both peered switches are aggregated to another device, the 
aggregated ports must be configured as a VLAG. For example, VLAGs 1 and 3 
must be configured for both VLAG Peer A switches. VLAGs 2 and 4 must be 
configured for both VLAG Peer B switches.VLAGs 3, 5, and 6 must be configured 
on both VLAG Peer C switches. Other devices connecting to the VLAG peers are 
configured using regular static or dynamic LAGs.
Note: Do not configure a VLAG for connecting only one switch in the peer set to 
another device or peer set. For instance, in VLAG Peer C, a regular LAG is 
employed for the downlink connection to VLAG Peer B because only one of the 
VLAG Peer C switches is involved.
188