6. Configure the upstream ports.
7. Configure the server ports.
8. Configure all VLANs including VLANs for the VLAGs.
204
G8264CS Application Guide for ENOS 8.4
RS 8264CS(config)# interface port 1
RS 8264CS(config-if)# switchport access vlan 30
RS 8264CS(config-if)# exit
RS 8264CS(config)# interface port 2
RS 8264CS(config-if)# switchport access vlan 40
RS 8264CS(config-if)# exit
RS 8264CS(config)# interface port 10
RS 8264CS(config-if)# switchport access vlan 100
RS 8264CS(config-if)# exit
RS 8264CS(config)# interface port 11
RS 8264CS(config-if)# switchport access vlan 100
RS 8264CS(config-if)# exit
RS 8264CS(config)# interface port 12
RS 8264CS(config-if)# switchport access vlan 100
RS 8264CS(config-if)# exit
RS 8264CS(config)# vlan 30
RS 8264CS(config-vlan)# exit
RS 8264CS(config)# interface port 1
RS 8264CS(config-if)# switchport mode trunk
RS 8264CS(config-if)# switchport trunk allowed vlan add 30
RS 8264CS(config-if)# exit
RS 8264CS(config)# vlan 40
RS 8264CS(config-vlan)# exit
RS 8264CS(config)# interface port 2
RS 8264CS(config-if)# switchport mode trunk
RS 8264CS(config-if)# switchport trunk allowed vlan add 40
RS 8264CS(config-if)# exit
RS 8264CS(config)# vlan 100
RS 8264CS(config-vlan)# exit
RS 8264CS(config)# interface port 4-5
RS 8264CS(config-if)# switchport mode trunk
RS 8264CS(config-if)# switchport trunk allowed vlan 100
RS 8264CS(config-if)# exit