Hot Links

Forward Delay

Preemption

FDB Update

Configuration Guidelines

© Copyright Lenovo 2017
Hot Links provides basic link redundancy with fast recovery.
Hot Links consists of up to 25 triggers. A trigger consists of a pair of layer 2 
interfaces, each containing an individual port, LAG, or LACP adminkey. One 
interface is the Master, and the other is a Backup. While the Master interface is set 
to the active state and forwards traffic, the Backup interface is set to the standby 
state and blocks traffic until the Master interface fails. If the Master interface fails, 
the Backup interface is set to active and forwards traffic. Once the Master interface 
is restored, it regains its active state and forwards traffic. The Backup transitions to 
the standby state.
You may select a physical port, static LAG, or an LACP adminkey as a Hot Link 
interface.
The Forward Delay timer allows Hot Links to monitor the Master and Backup 
interfaces for link stability before selecting one interface to transition to the active 
state. Before the transition occurs, the interface must maintain a stable link for the 
duration of the Forward Delay interval.
For example, if you set the Forward delay timer to 10 seconds, the switch will select 
an interface to become active only if a link remained stable for the duration of the 
Forward Delay period. If the link is unstable, the Forward Delay period starts 
again. 
You can configure the Master interface to resume the active state whenever it 
becomes available. With Hot Links preemption enabled, the Master interface 
transitions to the active state immediately upon recovery. The Backup interface 
immediately transitions to the standby state. If Forward Delay is enabled, the 
transition occurs when an interface has maintained link stability for the duration of 
the Forward Delay period.
Use the FDB update option to notify other devices on the network about updates to 
the Forwarding Database (FDB). When you enable FDB update, the switch sends 
multicasts of addresses in the forwarding database (FDB) over the active interface, 
so that other devices on the network can learn the new path. The Hot Links FBD 
update option uses the station update rate to determine the rate at which to send 
FDB packets.
The following configuration guidelines apply to Hot links:
When Hot Links is turned on, STP must be disabled on the hotlink ports.