EVB Configuration
1. Create an EVB profile.
2. Enable Reflective Relay.
3. Enable VSI discovery.
4. Enable a server port.
5. Add EVB profile to port.
6. Configure ECP retransmission interval.
350
G8264CS Application Guide for ENOS 8.4
This section includes the steps to configure EVB based on the following values:
Profile number: 1
Port number: 1
Retry interval: 8000 milliseconds
VSI Database:
Manager IP: 172.31.37.187
Port: 80
Note: VSI Database can be accessed via HTTP or HTTPS. The manager IP can be
configured with an IPv4 or IPv6 address.
RS 8264CS(config)# virt evb profile 1
RS 8264CS(conf-evbprof)# reflective-relay
RS 8264CS(conf-evbprof)# vsi-discovery
RS 8264CS(conf-evbprof)# exit
RS 8264CS(config)# system server-ports port <port‐number>
RS 8264CS(config)# interface port 1
RS 8264CS(config-if)# evb profile 1
ID)
RS 8264CS(config-if)# exit
RS 8264CS(config)# ecp retransmit-interval 8000
(Enter retransmission interval in milliseconds (100‐9000)
(Enter number from 1‐16)
(Enter EVB profile