Lenovo RackSwitch G8264CS Application Manual page 309

Hide thumbs Also See for RackSwitch G8264CS:
Table of Contents

Advertisement

2. Place FCoE ports into a VLAN supported by the FCF and CNAs (typically VLAN 
1002):
3. Turn CEE on.
4. Turn global FIP snooping on:
5. Enable FIP snooping on FCoE ports, and set the desired FCF mode:
© Copyright Lenovo 2017
RS 8264CS(config)# vlan 1002
RS 8264CS(config-vlan)# exit
RS 8264CS(config)# interface port 3,62
RS 8264CS(config-if)# switchport mode trunk
RS 8264CS(config-if)# switchport trunk allowed vlan add 1,1002
RS 8264CS(config-if)# exit
Note: The FCoE ports must also be members of VLAN 1 and the FCoE VLAN. The 
PVID of the FCoE ports must be 1 for them to discover FCF on the G8264CS.
RS 8264CS(config)# cee enable
Note: Turning CEE on will automatically change some 802.1p QoS and 802.3x 
standard flow control settings and menus (see "Turning CEE On or Off" on 
page
302).
RS 8264CS(config)# fcoe fips enable
RS 8264CS(config)# fcoe fips port 2 enable
RS 8264CS(config)# fcoe fips port 2 fcf-mode on
RS 8264CS(config)# fcoe fips port 3 enable
RS 8264CS(config)# fcoe fips port 3 fcf-mode off  (Set as ENode connection)
Note: By default, FIP snooping is enabled on all ports and the FCF mode set for 
automatic detection. The configuration in this step is unnecessary, if default 
settings have not been changed, and is shown merely as a manual configuration 
example.
(Select a VLAN)
(Exit VLAN configuration mode)
(Add FCoE ports to the VLAN)
(Enable FIPS on port 2)
  (Set as FCF connection)
 (Enable FIPS on port 3)
Chapter 17: FCoE and CEE
309