Storage Management Initiative Specification (Smi-S) - Lenovo RackSwitch G8264CS Application Manual

Hide thumbs Also See for RackSwitch G8264CS:
Table of Contents

Advertisement

Storage Management Initiative Specification (SMI-S)

Configuring SMI-S
SMI-S Restrictions
© Copyright Lenovo 2017
Lenovo Enterprise Network Operating System providges a programming interface 
using the SMI‐S to ease interoperability in a multivendor SAN environment. In this 
release, only limited support is provided. The G8264CS switch must be operating 
in full fabric mode. 
An embedded SMI‐S agent runs on the G8264CS and includes standard profiles as 
specified in the SMI‐S. These profiles include: 
Fabric Profile
Indication Profile
Server Profile
Switch Profile
You must the IBM Director (includes Tivoli Storage Productivity Center (TPC)) to 
configure and administer the fibre channel fabric, as configuring the switch, fabric, 
or ports via the CLI is not supported. Zoning control can be implemented and 
includes the following functions:
Session control (start, commit, and rollback)
Zoning updates
Create and destroy zone set, zone, and zone alias
Add/Remove zone to zone set, zone alias, or port WWN to zone and port WWN 
to zone alias
Activate and deactivate zoneset
Connection with the SMI‐S agent can be established via IPv4 or IPv6 management 
interface using HTTP/HTTPS. Use the following link: 
http://<Management IP address>:5988
(OR)
https://<Management IP address>:5989
The namespace for the SMI‐S agent is root/interop.
You will need to authenticate using the login and password configured for the 
switch.
The current implementation of SMI‐S does not support the following:
NPV mode
Switch port zoning
Zone configuration on the switch that uses FC IDs instead of port WWNs. 
Note: The CLI commands may be available, but the zone configuration will 
not be applied. 
Chapter 18: Fibre Channel