Establishing A Connection; Using The Switch Management Ports - Lenovo RackSwitch G8264CS Application Manual

Hide thumbs Also See for RackSwitch G8264CS:
Table of Contents

Advertisement

Establishing a Connection

Using the Switch Management Ports

1. Log onto the switch. 
2. Enter Global Configuration mode.  
3. Configure a management IP address and mask:
4. Configure the appropriate default gateway.
© Copyright Lenovo 2017
The factory default settings permit initial switch administration through only the 
built‐in serial port. All other forms of access require additional switch 
configuration before they can be used.
Remote access using the network requires the accessing terminal to have a valid, 
routable connection to the switch interface. The client IP address may be 
configured manually, or an IPv4 address can be provided automatically through 
the switch using a service such as DHCP or BOOTP relay (see "BOOTP/DHCP 
Client IP Address Services" on page
IPv6 stateless address configuration.
Note: Throughout this manual, IP address is used in places where either an IPv4 or 
IPv6 address is allowed. IPv4 addresses are entered in dotted‐decimal notation (for 
example, 10.10.10.1), while IPv6 addresses are entered in hexadecimal notation (for 
example, 2001:db8:85a3::8a2e:370:7334). In places where only one type of address is 
allowed, IPv4 address or IPv6 address is specified.
To manage the switch through the management ports, you must configure an IP 
interface for each management interface. Configure the IPv4 address/mask and 
default gateway address:
RS 8264CS> enable
RS 8264CS# configure terminal
RS 8264CS(config)# interface ip 128
RS 8264CS(config-ip-if)# ip address <management interface IPv4 address>
RS 8264CS(config-ip-if)# ip netmask <IPv4 subnet mask>
RS 8264CS(config-ip-if)# enable
RS 8264CS(config-ip-if)# exit
IP gateway 4 is required for IF 128. 
RS 8264CS(config)# ip gateway 4 address <default gateway IPv4 address>
RS 8264CS(config)# ip gateway 4 enable
Once you configure a management IP address for your switch, you can connect to 
a management port and use the Telnet program from an external management 
station to access and control the switch. The management port provides out‐of‐band 
management. 
41), or an IPv6 address can be obtained using 
Chapter 1: Switch Administration
33

Advertisement

Table of Contents
loading

Table of Contents