10. Configure the VLAN for VLAG 2. 
11. Map the VLAN to an MSTI. 
12. Disable VLAG. 
13. Add VLAG ports to the VLAN. 
14. Enable VLAG. 
15. Enable ISL ports and VLAG ports: 
16. Place the VLAG 2 ports in a port trunk group:
17. Assign the trunk to the VLAG:
198
G8264CS Application Guide for ENOS 8.4
RS 8264CS(config)# vlan 100
RS 8264CS(config-vlan)# exit
Note: The VLAN is automatically mapped to CIST.
RS 8264CS(config)# spanning-tree mst 1 vlan 100
Note: At this point, traffic may be momentarily disrupted due to STP 
recalculation.
RS 8264CS(config)# no vlag enable
Note: At this point, traffic may be momentarily disrupted due to STP 
recalculation.
RS 8264CS(config)# interface port 1-2,8
RS 8264CS(config-if)# switchport mode trunk
RS 8264CS(config-if)# switchport trunk allowed vlan 100
RS 8264CS(config-if)# exit
RS 8264CS(config)# vlag enable
Note: At this point, traffic may be momentarily disrupted due to STP 
recalculation.
On VLAG Peer 1:
RS 8264CS(config)# interface port 1-2,8
RS 8264CS(config-if)# no shutdown
On VLAG Peer2:
RS 8264CS(config)# interface port 8
RS 8264CS(config-if)# lacp mode active
RS 8264CS(config-if)# lacp key 1000
RS 8264CS(config-if)# exit
RS 8264CS(config)# vlag adminkey 1000 enable