When enabled for a specific application, automatically re-launches it (subject to the
specified Auto Re-Launch Delay in seconds) after it terminates. This option allows the
Administrator to disable the re-launch operation. AppLock cannot prevent all applica-
tions from closing. When an application that AppLock cannot prevent from closing ter-
minates, perhaps because of an error condition, AppLock re-launches the application
when this option is enabled.
Note: If Allow Close is enabled and both Auto Re-launch and Manual (Launch) are disabled, the
application cannot be restarted for the end-user or by the end-user after the application
terminates.
Retries
Default is 0 tries. Retries is the number of times AppLock will try to re-launch the appli-
cation. The retry count is reset after an application is successfully launched and con-
trolled by AppLock. Valid values are between 0 (no tries) and 99 tries or -1 for infinite.
Infinite tries ends when the application successfully launches.
Delay
Default is 0 seconds (no delay). Delay is the amount of time AppLock waits prior to re-
launching an application that has terminated. The delay is specified in seconds. Valid
values are between 0 (no delay) and 99 seconds.
AppLock must also be configured to automatically re-launch an application. To
AppLock, application termination by the end-user is indistinguishable from application
termination for any other reason.
Manual (Launch)
Default is Disabled. Enabling this option allows the end-user to launch the specified
application(s). Upon bootup completion an application with Manual enabled is listed on
the Switchpad accompanied by a check mark that indicates the application is currently
active or available for Launching. When an application name is tapped by the end-user,
the application is launched (if inactive) and brought to the foreground.
Applications set up with Manual (Launch) enabled may or may not be launched at boo-
tup. This function is based on the application's Auto At Boot setting. The applications
have been listed as approved applications for end-user manual launch using the
Switchpad menu structure. The approved applications are listed on the Switchpad. A
check mark indicates the applications active status.
When Manual (Launch) is disabled for an application, and Allow Close is enabled for the
application, when the end-user closes the specific application it is no longer available
(shown) on the Switchpad.
When Auto At Boot and Manual (Launch) are both disabled for a specific application,
the application is 1) not placed on the list of approved applications for end-user manual
launch and 2) never launched, and 3) not displayed on the Switchpad.
Allow Close
Default is Disabled. When enabled, the associated application can be closed by the end-
user.