Variable "TOOL_TEMP_COMP" (SD42960[...])
Temperature compensation referred to the tool
Address
DB120x.DBB1000
DB120x.DBB1001
DB120x.DBW1002
DB120x.DBW1004
DB120x.DBD1008
DB120x.DBW3004
14.6.1.9
Specifying selected NC variables
The selected NC variables are specified via the DB9910 data block (selected NC variable).
The length of the data block depends on the number of NC variables selected in the variables
list. The variables list can contain maximum 42 selected NC variables. The DB9910 data block
contains the data for variable addressing and data type conversion for each NC variable.
DB9910 (read selected NC variable)
DBB 0
DBB 1
DBB 2
DBB 3
DBW 4
DBW 6
DBB 8
DBB 9
DBB 10
DBB 11
DBB 492
DBB 493
DBB 494
DBB 495
DBW 496
DBW 498
DBB 500
DBB 501
DBB 502
DBB 503
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Value / meaning
17
-
Index + 1 (1, 2, 3)
-
Writing: Data to NCK variable x (data type: REAL)
Reading: Data from NCK variable x (data type: REAL)
....
P4: PLC for SINUMERIK 828D
(Interface: PLC → NC)
Variable index Variable 1
Syntax ID
Area
Unit
Column index
Line index
Block
Number of lines
Type
Length
.....
Variable index Variable 42
Syntax ID
Area
Unit
Column index
Line index
Block
Number of lines
Type
Length
14.6 Function interface
1113