Section 2 Engineering Guidelines
1.
EQUIPMENT DIMENSIONS
The Total Access 600R measures 11.25" W, 7.5" D, and 2" H and comes equipped for table top or wall
mount use.
2.
POWER REQUIREMENTS
The Total Access 600R has a maximum power consumption of 90-125 VAC 60 Hz and a maximum current
draw of 300 mA.
3.
REVIEWING THE FRONT PANEL DESIGN
Figure 1 shows the front panel of the Total Access 600R which contains the LAN, WAN, and power LEDs.
These LEDs and their functions are described in Table 1.
Front Panel LEDs
The front panel provides five status LEDs to monitor operation and activity. The following table provides
LED activity explanations.
For these LEDs...
LAN TX/RX
LAN LINK
WAN STAT
22
LAN
Figure 1. Total Access 600R Front Panel
Table 1. Total Access 600R Front Panel LEDs
This color light...
Off
Green (blinking)
Off
Green (solid)
Red (solid)
Yellow (solid)
Green (solid)
© 2002 ADTRAN, Inc.
Total Access 600R System Manual
Indicates that...
There is no data traffic on the LAN.
There is data traffic on the LAN.
The physical link is down; there is no Ethernet
connection.
There is link integrity on the LAN (physical link is up).
The T1 is in red alarm or T1 sync loss.
The T1 is in yellow alarm.
The unit is not in alarm.
WAN
61200600L1-1A