ADTRAN Total Access 600R System Manual page 137

Hide thumbs Also See for Total Access 600R:
Table of Contents

Advertisement

Total Access 600R System Manual
The unit contains six different password levels. The table below gives a brief description of each level.
Security Level
Full
Support
Config
Router
Status
In the A.03 firmware, only one Telnet session can be active at a time. The A.04 firmware
will support five simultaneous Telnet sessions.
In the A.03 firmware, the default conditions for the username and password fields are to
have no entries in these fields.
In the A.04 firmware, the default username and password are guest and password,
respectively.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.
61200600L1-1A
Description
The user has all access to view and configure all menus (same as logging in to
the CRAFT port).
The user has access to view S
change everything under the S
settings, T
A
ELNET
CCESS
user has full access to the S
firmware and reset the unit. The user has full access to the I
P
, B
, R
ROTOCOL
RIDGE
OUTER
ability to set R
ADIUS SERVER
The same privileges as support, except that the user does not have privileges to
download firmware or configuration from the S
additionally does not have the privilege to reset the unit remotely or enter the
terminal menu.
The user has view-only privileges of S
S
C
menu. The user has P
YSTEM
ONFIG
S
U
menu. The user is limited to Ethernet configuration and status
YSTEM
TILITY
from the I
menu. The user has full access to the B
NTERFACES
menus. Access is limited to filters only from the S
The user has read access of all menus except for the following: S
CRAFT P
, S
ORT
YSTEM
M
, and S
ANAGEMENT
ECURITY
to U
F
, U
PGRADE
IRMWARE
user cannot reset the unit or enter terminal mode.
© 2002 ADTRAN, Inc.
I
. The user has privileges to view and
YSTEM
NFO
C
menu except for the CRAFT port
YSTEM
ONFIG
lists, and the SNMP M
U
menu, including the ability to upgrade
YSTEM
TILITY
, and DS0 menus. The user does not have the
settings under the S
I
YSTEM
NFO
and T
ING
C
/T
A
ONFIG
ELNET
CCESS
/ R
S
. The user does not have access
ADIUS
ERVER
C
, P
PGRADE
ONFIG
ING
Section 5 DLP-003
C
ANAGEMENT
OMMUNITIES
NTERFACES
menu.
ECURITY
U
menu. The user
YSTEM
TILITY
. There is no access to the
access from the
RACEROUTE
and R
RIDGE
menu.
ECURITY
YSTEM
, S
C
/SNMP
YSTEM
ONFIG
, or T
menus. The
RACEROUTE
. The
, L2
OUTER
C
/
ONFIG