61210916L1-34G
April 2010
Total Access 900 Series
Hardware Installation Guide
Total Access 904
Total Access 908
Total Access 912
Total Access 916
Total Access 924

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN Total Access 904

  • Page 1 Total Access 900 Series Hardware Installation Guide Total Access 904 Total Access 908 Total Access 912 Total Access 916 Total Access 924 61210916L1-34G April 2010...
  • Page 2 Total Access® is a registered trademark of ADTRAN, Inc. To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice. In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication.
  • Page 3 Total Access 900 Series Hardware Installation Guide Conventions Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption or damage to the equipment. Warnings provide information that could prevent injury or endangerment to human life. 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 4 Additional safety and regulatory guidelines, such as Waste Electrical and Electronic Equipment (WEEE), are given in the NetVanta Safety and Regulatory Information document on the AOS Documentation CD. Save These Important Safety Instructions Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 5 Advance notification and the opportunity to maintain uninterrupted service are given. 4. If experiencing difficulty with this equipment, please contact ADTRAN for repair and warranty information. The telephone company may require this equipment to be disconnected from the network until the problem is corrected, or it is certain the equipment is not malfunctioning.
  • Page 6 Class A prescrites dans la norme sur le materiel brouilleur: “Appareils Numériques,” NMB-003 edictee par le ministre des Communications. Service and Warranty For information on the service and warranty of ADTRAN products, visit the ADTRAN website at http://www.adtran.com/support. Copyright © 2010 ADTRAN, Inc.
  • Page 7: Table Of Contents

    Contents of ADTRAN Total Access 900 Series Shipments ....... .
  • Page 8 Total Access 900 Series Hardware Installation Guide Table of Contents Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 9 Wall Mounting the 1175044L1 BBU ..........28 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 10 List of Figures Total Access 900 Series Hardware Installation Guide Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 11: List Of Tables

    Table A-6. CRAFT Port Pinouts............33 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 12 List of Tables Total Access 900 Series Hardware Installation Guide Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 13: Introduction

    (CLECs), incumbent local exchange carrieres (ILECs), and Internet service providers (ISPs). Total Access 900 Series products are built on the ADTRAN Operating System (AOS) platform and include the AOS built-in IP router and firewall features. The units include a T1 network interface (...
  • Page 14: Unpack And Inspect The System

    After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact contact ADTRAN Customer Service (refer to Service and Warranty on page...
  • Page 15: Physical Description

    Total Access 916 contains 16 FXS ports, and the Total Access 924 contains 24 FXS ports or 16 FXS ports plus 8 FXO ports with octal FXO daughterboard). Total Access 904 Total Access 908 Total Access 912 Total Access 916 Total Access 924 Figure 1. Total Access 900 Series Front Panel Layouts 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 16: Front Panel Leds

    Green (off) Link is down or port is administratively shut down. (Rear Panel) Green (solid) Link is up. Amber (off) No traffic present or port is administratively shut down. Amber (flashing) Data traffic is flowing. Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 17: Reviewing The Rear Panel Design

    Ethernet port. The green link LED is on when the unit has a good connection to the LAN. See Table A-5 on page 32 for the Ethernet port pinouts. 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 18 Table A-2 on page 32 for the ADSL network interface pinouts. DSX-1 Interface interface is a DSX-1 RJ-48C pin connection. See Table A-4 on page 32 for the DSX-1 T1 0/2 DSX-1 network interface pinouts. Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 19: Figure 3. Voice Connector Pin Assignments

    1 through 8. The Total Access 912 only uses circuits 1 through 12. The Total Access 916 only uses circuits 1 through 16. The Total Access 924 uses all circuits (1 through 24), and the FXO interfaces are on circuits 17 through 24. 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 20: Unit Installation

    • Refer to your Total Access 900 Series quick start guide provided on the AOS Documentation CD or available online at http://kb.adtran.com for instructions on how to access the GUI and the CLI. Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 21: Mounting Options

    Have an assistant hold the unit in position as you install two 3/32-inch up to 1/8-inch (1-inch or greater length) wood screws through the unit’s brackets and into the mounted board. Proceed to the steps given in Grounding Instructions on page 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 22: Rack Mounting Total Access 900 Series

    The Total Access 912/916/924 mount and connect with standard fasteners and hand tools. The Total Access 904 and Total Access 908 are not rack mountable. ADTRAN recommends 1U (1.75 inches) of separation above and below the Total Access 900 Series unit. This spacing allows the unit to dissipate heat. The design of the Total Access 900 Series uses the chassis to distribute heat generated by the unit’s...
  • Page 23: Grounding Instructions

    61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 24: Grounding For Ac Power

    Install unit in accordance with Article 400 and 364.8 of the NEC NFPA 70. • A readily accessible disconnect device, that is suitably approved and rated, shall be incorporated in the field wiring. ° • Maximum recommended ambient operating temperature is 50 Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 25: Battery Backup Unit

    Total Access 900 Series Hardware Installation Guide Battery Backup Unit BATTERY BACKUP UNIT The ADTRAN battery backup unit (BBU) is an optional device designed as a backup DC power supply for the Total Access 900 Series. Total Access 904/908 BBU (P/N 1200641L1) The BBU connects to the Total Access 904/908 through a 2-foot charge/discharge, 2-conductor wire with a keyed modular plug (included with the BBU).
  • Page 26: Unpack And Inspect The Bbu

    BBU Safety and EMC Notices The BBU should only be used in specified ADTRAN applications. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: •...
  • Page 27: Wall Mounting The Bbu

    Position the BBU and to hang on the screw heads. Allow the unit to slide down until the slot end rests against the screws. Use cable ties as appropriate. The battery connection from the BBU should be directly connected to the BATT port on the rear of the chassis. 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 28: Wall Mounting The Total Access 912/916/924 Bbu

    Insert the two lower screws through the tabs and tighten securely. Use cable ties as appropriate. The battery connection from the BBU should be directly connected to the BATT port on the rear of the chassis. Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 29: Maintenance

    To order replacement batteries, reference the following part number: 1975044L1 (12 V replacement batteries). ADTRAN is an environmentally friendly company. Therefore, we encourage the proper recycling and handling of the batteries. Federal and state laws prohibit the improper disposal of all lead acid batteries.
  • Page 30 Battery Backup Unit Total Access 900 Series Hardware Installation Guide Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 31: Appendix A. Pin Assignments

    FXS 0/23 Ring, Tip or FXO 0/7 Ring, Tip 24, 49 Circuit 24 FXS 0/24 Ring, Tip or FXO 0/8 Ring, Tip 25, 50 — Unused Note: The FXO ports are only available on the Total Access 924. 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 32: Table A-2. Net (T1 0/1) Pinouts

    Receive data from the DTE (Ring 1) Receive data from the DTE (Tip 1) — Unused Table A-5. 10/100Base-T (ETH 0/1) Pinouts Name Description Transmit Positive Transmit Negative Receive Positive 4, 5 — Unused Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 33: Table A-6. Craft Port Pinouts

    Ground - connected to unit chassis Data Set Ready (output) Request To Send - flow control (input) Clear To Send - flow control (output) Ring Indicate (output) Connection directly to an external modem requires a cross-over cable. 61210916L1-34G Copyright © 2010 ADTRAN, Inc.
  • Page 34 Appendix A Total Access 900 Series Hardware Installation Guide Copyright © 2010 ADTRAN, Inc. 61210916L1-34G...
  • Page 35: Index

    20 the system 14 rackmount 23 wallmount 21 installing 20 voice 50-pin amphenol 19 pinouts 19 LEDs front panel 16 rear panel 17 wall mounting 21 installation of battery backup unit 27 warranty 6 61210916L1-34G Copyright © 2010 ADTRAN, Inc.