ABB SACE Tmax XT5 Operation And Maintenance Manual page 194

Tmax low voltage moulded-case circuit-breakers xt5
Hide thumbs Also See for SACE Tmax XT5:
Table of Contents

Advertisement

Power supply Ekip Com Hub is supplied directly by the Ekip Touch to which it is connected.
Configurations via menu Local bus activation, which is essential for starting the communication between module and Ekip Touch, is
Information in menu The following information will be available in the About-Modules menu if Ekip Touch has detected the module
192 | © 2019 ABB | 1SDH002039A1002 - ECN000093027 - Rev. A
NOTE: communication between Ekip Touch and the module is interrupted in the absence of
auxiliary power supply
available in the Settings menu (page 33).
The following communication parameters can be configured if the module has been correctly detected by
Ekip Touch in the Settings-Modules menu:
Parameter
Description
Enable
Switches communication between module and server on/off.
Defines whether the module has the dynamic (Off) or static (On) IP
Force Static IP
address.
Address ON
If = On all the associated parameters are enabled
Static address
Enables the static IP to be selected
IP address
Static Network
Enables the subnet mask to be selected
Mask
When there are several subnets, enables the IP address of the node to
Static Gateway
address
which the module is connected to be selected
Allows the SNTP protocol for distribution of the clock and
Enable SNTP
client
synchronization signal to be enabled.
SNTP Server
Allows the network server that supplies the SNTP to be set.
Addr.
Password
code required to register module on Cloud
Enables the firmware of the module to be updated. There are two
Remote
parameters:
• Enable, to configure firmware download
firmware update
• Automatic, to automate module updating
correctly:
Information
Description
SN and version
Identifier and SW version of the module
Address of the module, assigned to the module by a DHCP server at the time of
connection to the network in the case of configuration with a dynamic IP, or can be
set via the menu in the event of a static IP.
IP address
NOTE:without a DHCP server, the module automatically adopts a random IP
address within the 169.254.xxx.xxx range
Subnet mask; identifies the method for recognizing the subnet to which the modules
Network Mask
belong and enables modules to be searched for within a defined set of recipients.
IP address of the node to which the module is connected, in the presence of several
Gateway address
subnets
Address assigned by ABB, with OUI (Organizationally Unique Identifier) equal to
MAC address
ac:d3:64, which uniquely identifies the manufacturer of an Ethernet device
ABB | SACE Tmax XT
Default
Off
0.0.0.0
0.0.0.0
0.0.0.0
Off
0.0.0.0
---
Off
Automatic
Internal accessories | 7 - Ekip Com Hub