6 Data Interfaces
6.4 Device connection data
Siemens Programmer
PG 685/675/670/730/750
Interface S5 PLC
Cable Order No.:
6FC9 340-8G
6FC9 344-4R
(PG 730/750 only)
Device data
Interface:
Transfer rate:
Character format:
Operating conditions
For PLC programming the
PG685/675/670/750 Programmer should
be connected directly to Interface 1 (20
mA current loop interface) on the
SINUMERIK 810M.
(If cable 6FC9340-8G is used with the PG
750, the supplied adaptor must be used)
Siemens Programmer PG 675/685
Interface printer
Cable Order No.:
Device data
Interface
Transfer rate
Character format
Operating conditions
Archiving of NC cycles and programs on disk,
and the transfer to and from the NC and the
creation of programs is possible with the PG
675/685. For data transfer, the PG 675/685
should be connected from the printer
interface to an RS232C (V.24) interface on the
SINUMERIK 810M.
6-6
Siemens Programmer PG 615 U with
PG 615 adapter and power pack
Interface PLC
Cable Order No.:
Device data
Interface
20 mA current
loop
Transfer rate
9600 baud
Character format
1 Start bit,
7 Data bits,
1 Parity bit (even
parity),
2 Stop bits
Operating conditions
For PLC programming the PG615 Program-
mer is connected via the adapter and a
cable to Interface 1 (20 mA current loop)
on the SINUMERIK 810M.
6FC9 344-1A.
RS232C (V.24)
1200 baud
1 Start bit
8 Data bits
2 Stop bits
© Siemens AG 1990 All Rights Reserved
01.93
6FC9 340-8H.
20 mA current
loop
9600 baud
1 Start bit
7 Data bits
1 Parity bit
(even parity)
2 Stop bits
6ZB5 410-0EQ02
SINUMERIK 810M, GA3 (BN)