01.93
3.2.3.4 Interrupting the program
Sequence of operation
You can interrupt a running program in one of the following ways:
1) Perform one of the operating mode changes which causes a RESET (see Section
2.3.4). The drives are brought to a controlled standstill.
2) By NC STOP:
The axis positions programmed in the current block are
© Siemens AG 1990 All Rights Reserved
SINUMERIK 810M, GA3 (BN)
Operate the "NC STOP" key.
The drives are brought to a controlled standstill
without leaving the programmed path.
The STOP: "AUTO INTERRUPTED" display appears.
Now operate the keys "NC Start" and "Feed On".
The feed is enabled.
approached with linear interpolation.
Caution: danger of collision!!
6ZB5 410-0EQ02
3 Operating Sequences
3.2.3 Influencing "AUTOMATIC" operation
3-107